![Allen-Bradley 1783-WAPAK9 Скачать руководство пользователя страница 211](http://html1.mh-extra.com/html/allen-bradley/1783-wapak9/1783-wapak9_user-manual_2900827211.webp)
Rockwell Automation Publication 1783-UM006A-EN-P - May 2014
211
Administering the WAP Access
Chapter 6
Defining AAA Server Groups
You can configure the wireless device to use AAA server groups to group existing
server hosts for authentication. You choose a subset of the configured server hosts
and use them for a particular service. The server group is used with a global
server-host list, that lists the IP addresses of the selected server hosts.
Server groups also can include multiple host entries for the same server if each
entry has a unique identifier (the combination of the IP address and UDP port
number), letting different ports to be individually defined as RADIUS hosts
providing a specific AAA service. If you configure two different host entries on
the same RADIUS server for the same service (such as accounting), the second
configured host entry acts as a fail-over backup to the first one.
You use the
server
group server configuration command to associate a
particular server with a defined group server. You can either identify the server by
its IP address or identify multiple host instances or entries by using the optional
auth-port
and
acct-port
keywords.
Beginning in privileged EXEC mode, follow these steps to define the AAA server
group and associate a particular RADIUS server with it:
1.
Enter global configuration mode.
configure terminal
2.
Enable AAA.
aaa new-model
3.
Specify the IP address or host name of the remote RADIUS server host.
radius-server host {hostname | ip-address} [auth-
port port-number] [acct-port port-number] [timeout
seconds] [retransmit retries] [key string]
•
(Optional) For
auth-port port-number
, specify the UDP
destination port for authentication requests.
•
(Optional) For
acct-port port-number
, specify the UDP
destination port for accounting requests.
•
(Optional) For
timeout seconds
, specify the time interval that the
wireless device waits for the RADIUS server to reply before
retransmitting. The range is 1…1000. This setting overrides the
radius-server timeout
global configuration command setting.
If no timeout is set with the
radius-server host
command, the
setting of the
radius-server timeout
command is used.
•
(Optional) For
retransmit retries
, specify the number of times
a RADIUS request is resent to a server if that server is not responding
or responding slowly. The range is 1…1000. If no retransmit value is set
with the
radius-server host
command, the setting of the
radius-server retransmit
global configuration command is
used.
Содержание 1783-WAPAK9
Страница 240: ...240 Rockwell Automation Publication 1783 UM006A EN P May 2014 Chapter 6 Administering the WAP Access Notes...
Страница 300: ...300 Rockwell Automation Publication 1783 UM006A EN P May 2014 Chapter 8 Configuring Multiple SSIDs Notes...
Страница 440: ...440 Rockwell Automation Publication 1783 UM006A EN P May 2014 Chapter 14 Configuring RADIUS and TACACS Servers Notes...
Страница 456: ...456 Rockwell Automation Publication 1783 UM006A EN P May 2014 Chapter 15 Configuring VLANs...
Страница 476: ...476 Rockwell Automation Publication 1783 UM006A EN P May 2014 Chapter 16 Configuring QoS Notes...
Страница 482: ...482 Rockwell Automation Publication 1783 UM006A EN P May 2014 Chapter 17 Configuring Filters...
Страница 489: ...Rockwell Automation Publication 1783 UM006A EN P May 2014 489 Configuring Filters Chapter 17...
Страница 520: ...520 Rockwell Automation Publication 1783 UM006A EN P May 2014 Chapter 19 Configuring SNMP Notes...
Страница 572: ...572 Rockwell Automation Publication 1783 UM006A EN P May 2014 Chapter 21 Troubleshooting Notes...
Страница 578: ...578 Rockwell Automation Publication 1783 UM006A EN P May 2014 Appendix A Protocol Filters Notes...
Страница 594: ...594 Rockwell Automation Publication 1783 UM006A EN P May 2014 Appendix C Error and Event Messages Notes...
Страница 600: ...600 Rockwell Automation Publication 1783 UM006A EN P May 2014 Glossary Notes...
Страница 610: ...610 Rockwell Automation Publication 1783 UM006A EN P May 2014 Index Notes...
Страница 611: ......