![Allen-Bradley 1783-WAPAK9 Скачать руководство пользователя страница 433](http://html1.mh-extra.com/html/allen-bradley/1783-wapak9/1783-wapak9_user-manual_2900827433.webp)
Rockwell Automation Publication 1783-UM006A-EN-P - May 2014
433
Configuring RADIUS and Servers
Chapter 14
lets a conversation to be held between the daemon and the
administrator until the daemon receives enough information to
authenticate the administrator. The daemon prompts for a username and
password combination, but can include other items, such as the user’s
mother’s maiden name.
4.
The access point eventually receives one of these responses from the
daemon.
After authentication, the administrator undergoes an additional
authorization phase if authorization has been enabled on the access point.
Administrators must first successfully complete
authentication before proceeding to authorization.
5.
If authorization is required, the daemon is again
contacted, and it returns an ACCEPT or REJECT authorization
response. If an ACCEPT response is returned, the response contains data
in the form of attributes that direct the EXEC or NETWORK session for
that administrator, determining the services that the administrator can
access:
•
Telnet, rlogin, or privileged EXEC services
•
Connection parameters, including the host or client IP address, access
list, and administrator timeouts
Configuring
To configure your access point to support , you must identify the host
or hosts maintaining the daemon and define the method lists for
authentication. You can optionally define method lists for
authorization and accounting.
A method list defines the sequence and methods to be used to authenticate, to
authorize, or to keep accounts on an administrator. You can use method lists to
designate one or more security protocols to be used, thus ensuring a back-up
system if the initial method fails.
The software uses the first method listed to authenticate, to authorize, or to keep
accounts on administrators; if that method does not respond, the software selects
the next method in the list. This process continues until there is successful
communication with a listed method or the method list is exhausted.
Response
Description
ACCEPT
The administrator is authenticated and service can begin. If the access point is configured
to require authorization, authorization begins at this time.
REJECT
The administrator is not authenticated. The administrator can be denied access or is
prompted to retry the login sequence, depending on the daemon.
ERROR
An error occurred at some time during authentication with the daemon or in the network
connection between the daemon and the access point. If an ERROR response is received,
the access point typically tries to use an alternative method for authenticating the
administrator.
CONTINUE
The administrator is prompted for additional authentication information.
Содержание 1783-WAPAK9
Страница 240: ...240 Rockwell Automation Publication 1783 UM006A EN P May 2014 Chapter 6 Administering the WAP Access Notes...
Страница 300: ...300 Rockwell Automation Publication 1783 UM006A EN P May 2014 Chapter 8 Configuring Multiple SSIDs Notes...
Страница 440: ...440 Rockwell Automation Publication 1783 UM006A EN P May 2014 Chapter 14 Configuring RADIUS and TACACS Servers Notes...
Страница 456: ...456 Rockwell Automation Publication 1783 UM006A EN P May 2014 Chapter 15 Configuring VLANs...
Страница 476: ...476 Rockwell Automation Publication 1783 UM006A EN P May 2014 Chapter 16 Configuring QoS Notes...
Страница 482: ...482 Rockwell Automation Publication 1783 UM006A EN P May 2014 Chapter 17 Configuring Filters...
Страница 489: ...Rockwell Automation Publication 1783 UM006A EN P May 2014 489 Configuring Filters Chapter 17...
Страница 520: ...520 Rockwell Automation Publication 1783 UM006A EN P May 2014 Chapter 19 Configuring SNMP Notes...
Страница 572: ...572 Rockwell Automation Publication 1783 UM006A EN P May 2014 Chapter 21 Troubleshooting Notes...
Страница 578: ...578 Rockwell Automation Publication 1783 UM006A EN P May 2014 Appendix A Protocol Filters Notes...
Страница 594: ...594 Rockwell Automation Publication 1783 UM006A EN P May 2014 Appendix C Error and Event Messages Notes...
Страница 600: ...600 Rockwell Automation Publication 1783 UM006A EN P May 2014 Glossary Notes...
Страница 610: ...610 Rockwell Automation Publication 1783 UM006A EN P May 2014 Index Notes...
Страница 611: ......