background image

 

  ATTENTION:  Any  person  who  performs  the  interventions  on  the  product  must  first  read  and  fully  understand  the 

contents of this manual and be fully familiar with the control panel of the product.

 

 ATTENTION:  The  product  may  be  used,  changed  and  programmed  only  by  adults.  In  accurate  or  random  settings 

may lead to dangerous situations or malfunctions.

 

  ATTENTION:  The  company  Alfa  Plam  bears  no  civil  or  criminal  liability  for  damages  in  the  event  the  product  is 

subjected to unauthorised repairs or replacement of parts.

 

 ATTENTION: While the product is in operation, some of its surfaces may reach extremely high temperatures.

 

Therefore,  the  user  is  advised  to  take  all  the  necessary  precautions,  especially  when  children  or  elderly  or  disabled 

people are present.

 

 ATTENTION: Do not cover or close the hot air outlet in any way. Do not cover the product with any cloth or any similar 

material.

 

 ATTENTION: To avoid accidental tipping over of the furnace, never lean or place too much weight on the open door 

while the cleaning procedure is in progress. 

 

It  is  recommended  to  avoid  this  kind  of  pressure  and  take  the  necessary  precautions,  especially  when  children  or 

elderly or disabled people are present. 

 

 

General recommendations 

 ATTENTION: Never use the product for purposes other than those for which it is designed and manufactured.

 

 ATTENTION: The product must not be used for cooking.

 

  ATTENTION:  The  product  should  not  be  used  in  the  event  of  any  failure  or  malfunction.  In  such  a  situation, 

disconnect the power cord from the socket immediately.

 

NEVER leave the product door open while the furnace is operating.

 

Pipes have to be regularly inspected.

 

NEVER use steam for cleaning of the product.

 

Always consult qualified and authorised personnel for any service interventions that may be necessary. Use only the 

original spare parts.

 

Fuel in the burner can be fed only through an automated feeding system and not directly by the user.

 

 ATTENTION: In the case of "failed ignition“, you must remove all the pellets deposited in the combustion chamber 

before you try to re-ignite the furnace. The pellet removed from the furnace must not be returned to the tank.

 

This manual must be considered an integral part of the product and must be used over its entire service life. It has to 

be kept at a safe location. In case the manual is lost or damaged, a replacement copy can be obtained from your dealer. 

 

 

Safety device 

The product is equipped with the following safety devices:

 

• 

Thermostat for determining the temperature of the tank: This device shuts down operation of the product each 

time the set safety limit is exceeded;

 

• 

Meter  for  determining  the  temperature  of  smoke:  this  element  establishes  the  temperature  of  smoke  and 

continually monitors the proper functioning of the product;

 

• 

Pressure switch:this element assesses whether the pipe is clogged;

 

• 

Thermometer  for  the  environment:  this  element  constantly  monitors  the  temperature  of  the  room  where  the 

furnace is located;

 

• 

Modulation  mode  of  operation:  if  the  flue  gas  temperature  exceeds  the  set  safety  threshold,  the  device  will 

automatically reduce the amount of pellets for burning until the temperature drops below the pre-set limit.

 

Incorrect parameter settings can lead to exceeding the safety limits and can lead to excessive consumption of pellets. 

The exceeding the safety limits can also be caused by poor ventilation of the environment in which the furnace is located 
which presents the device to get enough cold air

 

IT IS FORBIDDEN TO shut down the safety devices. When you eliminate the cause of the security system activation, 

the device can be restarted in order to restore its proper functioning.

 

 ATTENTION: The device must be installed in such a way that the electrical cable can be easily reached.

 

Note:  The  security  section  is  made  taking  into  account  the  normal  conditions  of  use  of  the  product  described  and 

specified in the chapter 3. The company Alfa Plam bears no responsibility for any personal injury or property damage that 
may occur if the furnace is not used in accordance with the conditions specified in this user manual. The company Alfa 
Plam also bears no responsibility for any personal injury or property damage that may occur if the user fails to comply with 
the following regulations: 

A) 

They must take all the necessary measures and precautions to ensure that no party activates equipment until 

the repairs, adjustments, replacement, or maintenance operations are completed;

 

B) 

Do not remove or change any safety devices on the device;

 

C) 

The device must be connected to the system for extracting of smoke which is functioning correctly;

 

D) 

Make sure that the environment in which the furnace is installed is sufficiently ventilated, as prescribed in this 

manual.

 

 

 

Environment for the use of the product

 

 ATTENTION: The device must be installed in an environment with ventilation, whereas in accordance with the current 

regulations it must be provided with sufficient combustion air. This is important to ensure its proper functioning.

 

Содержание LUCA S

Страница 1: ...his user manual is an integral part of the product It has to be kept and read carefully METAL INDUSTRY VRANJE st Radni ka n 1 PELLET STOVE LUCA S LUCA S8 INSTRUCTIONS FOR ASSEMBLY USE AND MAINTENANCE...

Страница 2: ...ommissioning is performed by qualified personnel Do not use any flammable liquids for the ignition process This product should not be used by people with reduced physical sensory and mental abilities...

Страница 3: ...essary controls and checks for first ignition 9 3 2Fuel feed 9 4 Furnace management system 10 4 1Electric wiring scheme 10 4 2The control panel display use and functions 11 4 2 1 Display K100 11 4 2 2...

Страница 4: ...oblems and solutions 17 5 STOVE MAINTENANCE 18 5 1Routine maintenance 18 5 1 1 CLEANING OF THE DISPLAY AND PARTS OF THE EXTERNAL INSULATION 18 5 1 2 CLEANING OF THE CERAMIC GLASS 18 5 1 3 ROUTINE MAIN...

Страница 5: ...gher level and so as to improve the final product Seals which provide sealing of the combustion chamber must be periodically inspected to prevent undesirable combustion which may occur due to excessiv...

Страница 6: ...3 2 7 Emission of CO at 13 of oxygen 0 0136 0 0213 Efficiency 85 57 92 27 Rated electric energy W 380 Rated voltage V 230 Rated frequency Hz 50 Fuel Pellet Fuel consumption per hour kg h 1 608 0 642...

Страница 7: ...to 8 mm in the radius Wood pellets are primarily characterised by low humidity below 12 and high density 600 kg m3 as well as by its uniformity and compactness which gives this type of fuel high calor...

Страница 8: ...by the manufacturer may lead to failure of the furnace and may void the warranty When feeding the pellets be careful the pellet does not fall into another internal part of the furnace other than the s...

Страница 9: ...he product is equipped with the following safety devices Thermostat for determining the temperature of the tank This device shuts down operation of the product each time the set safety limit is exceed...

Страница 10: ...diminished 4 Have to be placed so that they are not covered in any way Adequate fresh air flow can also be provided using the opening to the next room if the room is equipped with direct ventilation a...

Страница 11: ...I Maximum height of the pipe which is connected directly to the smoke outlet in the furnace should be between 2 to 3 m If you need a horizontal segment ensure that it does not exceed 1 5 m in length a...

Страница 12: ...er resistance to atmospheric conditions as well as the proper temperature of exhaust gases themselves 2 2 2 Smoke outlet at the roof through the traditional chimney Exhaust gases from the furnace can...

Страница 13: ...ring first ignition Check whether all safety requirements have been met see section 1 8 Connect the device to the power supply only when you are sure that the supply voltage is 230 V 50 Hz When you co...

Страница 14: ...ace an advanced control system is installed which provides a safe efficient and reliable management of the operation and maximum functional use of the furnace It is characterised by Simplicity of sett...

Страница 15: ...escription System condition Code Safety error safety thermostat signals when the system is off Block Er01 Safety error pressure control signals only if the combustion fan is turned on Block Er02 Shutt...

Страница 16: ...bmenu Combustion Management Combustion management Power In this sub menu it is possible to modify the system combustion power Use the P4 and P5 buttons to select from 5 powers Power 1 Power 2 Power 3...

Страница 17: ...the P1 button Disabled Daily Weekly Week End Chrono Program Chrono program provides three types of programming Daily weekly and weekend After entering the Chrono program the following message appears...

Страница 18: ...sible to choose between programs Mon Fri Sat Sun The selected programs will be active for the days from Monday to Friday or Saturday and Sunday The programs are activated and deactivated in the same w...

Страница 19: ...ue gas motor are active Ignition Fixed Phase This phase represents a fixed time period that lasts 180 seconds and in case the requirements for the ignition of the furnace are reached before the expira...

Страница 20: ...ge Er11 indicating that the DATE TIME is not accurate Deblock using the P1 button the value of TIME flashes signalling the need for updating the TIME and DATE with the function CLOCK 4 6 2 Pellet feed...

Страница 21: ...of pellet in the burning unit is too low or too high Wait for the furnace to extinguish and then press and hold P2 button for more than 3 seconds Check the size of the pellet Check the cleanliness of...

Страница 22: ...not achieved The presence of some large obstacle or debris in the pipe for entry of primary air Wait for the furnace to extinguish and then press and hold P2 button for more than 3 seconds Check and...

Страница 23: ...tenance of the furnace ATTENTION Each cleaning activity has to be performed when the furnace is completely cold and disconnected from the power supply with the cable pulled out from the socket Number...

Страница 24: ...ties Type 2 must be carried out at about 350 400 hours or else after about 500 600 kg of fuel ATTENTION Each cleaning activity has to be performed when the furnace is completely cold and disconnected...

Страница 25: ...can be removed These parts usually must be replaced every three years depending on the type of furnace the intensity of use etc Seals must be elastic at touch and must be replaced if they become tota...

Отзывы: