Shutting down during the ignition phase

 

When the system is turned off during the ignition phase (after the preheater phase) through an external device or internal 

Chrono device, the system goes into shutdown phase when it enters the mode of operation at the end of ignition. The display 
will show the message Block ignition. 

If an error occurs, the system immediately shuts down; If the P2 button is pressed, it is possible to immediately introduce 

the system in the shut down or start up condition.

 

 

 

Potential problems and solutions  

Display 

message 

Description 

Potential causes 

Error reset 

Potential solutions 

for the cause of the 

alarm 

 
 
 
 
Er01 

 
 
 
 
Activation of 

the safety 
thermostat 

 
High temperature inside the 

furnace 

Wait until the oven has 

cooled and then unscrew 
the plastic cap on the 
thermostat and press the 
reset button 

Check the heat 

outputs i.e. that there 
are no obstacles for 
the passage of hot air  

Excessive temperature in 

the room where the furnace is 
installed 

Contact the repair 

shop 

Faulty thermostat 

 
 
Er02 

 
 
Activation of 

the safety pressure 
switches 

Obstruction of the flue gas 

outlet 

 
Press and hold P2 

button for more than 3 
seconds 

Check the 

cleanliness of flue 
pipes and chimneys  

Faulty chimney installations 

 
Contact the repair 

shop 

Faulty pressure switch 

 
 
 
Er03 

 
 
Shutting off due 

to too low flue gas 
temperature. 

Bad combustion (the 

amount of pellet in the burning 
unit is too low or too high) 

 
Wait for the furnace to 

extinguish and then press 
and hold P2 button for 
more than 3 seconds 

Check the size of 

the pellet 

Check the 

cleanliness of the 
furnace chamber 

Pellet tank empty 

Check the 

condition of the flue 
ducts 

Faulty flue gas probe 

Contact the repair 

shop 

 
 
Er05 

 
Shutting off due 

to too high flue gas 
temperature. 

Flue gas temperature 

exceeds the limit 

 
Wait for the furnace to 

extinguish and then press 
and hold P2 button for 
more than 3 seconds 

Insufficient heat 

transfer - call the 
repair shop 

Obstruction of the flue gas 

outlet 

Check the 

cleanliness of the flue 
duct and chimney 

Faulty flue gas probe 

 
Er07 

 
Encoder error  

 
Encoder signal missing 

Wait for the furnace to 

extinguish and then press 
and hold P2 button for 
more than 3 seconds 

 
Contact the repair 

shop 

 
 
Er08 

 
 
Encoder error 

Flue gas motor does not 

respond 

Wait for the furnace to 

extinguish and then press 
and hold P2 button for 
more than 3 seconds 

 
 
Contact the repair 

shop 

The flue gas motor works at 

the speed different from the set 
speed 

 
 
Er11 

 
 
Clock error 

Problems with the internal 

clock 

 
Press and hold P2 

button for more than 3 
seconds 

Check the 

accuracy of the set 
time 

 
Insufficient capacity of the 

internal battery 

Check the 

accuracy of 
programming in the 
Chrono mode of work 

Contact the repair 

shop 

 
 
 
Er12 

 
 
 
Failed ignition 

Error during the ignition of 

the furnace 

 
Wait for the furnace to 

extinguish and then press 
and hold P2 button for 

Check the 

condition and the 
quality of the pellet 
being used 

During the entire duration of 

Содержание LUCA S

Страница 1: ...his user manual is an integral part of the product It has to be kept and read carefully METAL INDUSTRY VRANJE st Radni ka n 1 PELLET STOVE LUCA S LUCA S8 INSTRUCTIONS FOR ASSEMBLY USE AND MAINTENANCE...

Страница 2: ...ommissioning is performed by qualified personnel Do not use any flammable liquids for the ignition process This product should not be used by people with reduced physical sensory and mental abilities...

Страница 3: ...essary controls and checks for first ignition 9 3 2Fuel feed 9 4 Furnace management system 10 4 1Electric wiring scheme 10 4 2The control panel display use and functions 11 4 2 1 Display K100 11 4 2 2...

Страница 4: ...oblems and solutions 17 5 STOVE MAINTENANCE 18 5 1Routine maintenance 18 5 1 1 CLEANING OF THE DISPLAY AND PARTS OF THE EXTERNAL INSULATION 18 5 1 2 CLEANING OF THE CERAMIC GLASS 18 5 1 3 ROUTINE MAIN...

Страница 5: ...gher level and so as to improve the final product Seals which provide sealing of the combustion chamber must be periodically inspected to prevent undesirable combustion which may occur due to excessiv...

Страница 6: ...3 2 7 Emission of CO at 13 of oxygen 0 0136 0 0213 Efficiency 85 57 92 27 Rated electric energy W 380 Rated voltage V 230 Rated frequency Hz 50 Fuel Pellet Fuel consumption per hour kg h 1 608 0 642...

Страница 7: ...to 8 mm in the radius Wood pellets are primarily characterised by low humidity below 12 and high density 600 kg m3 as well as by its uniformity and compactness which gives this type of fuel high calor...

Страница 8: ...by the manufacturer may lead to failure of the furnace and may void the warranty When feeding the pellets be careful the pellet does not fall into another internal part of the furnace other than the s...

Страница 9: ...he product is equipped with the following safety devices Thermostat for determining the temperature of the tank This device shuts down operation of the product each time the set safety limit is exceed...

Страница 10: ...diminished 4 Have to be placed so that they are not covered in any way Adequate fresh air flow can also be provided using the opening to the next room if the room is equipped with direct ventilation a...

Страница 11: ...I Maximum height of the pipe which is connected directly to the smoke outlet in the furnace should be between 2 to 3 m If you need a horizontal segment ensure that it does not exceed 1 5 m in length a...

Страница 12: ...er resistance to atmospheric conditions as well as the proper temperature of exhaust gases themselves 2 2 2 Smoke outlet at the roof through the traditional chimney Exhaust gases from the furnace can...

Страница 13: ...ring first ignition Check whether all safety requirements have been met see section 1 8 Connect the device to the power supply only when you are sure that the supply voltage is 230 V 50 Hz When you co...

Страница 14: ...ace an advanced control system is installed which provides a safe efficient and reliable management of the operation and maximum functional use of the furnace It is characterised by Simplicity of sett...

Страница 15: ...escription System condition Code Safety error safety thermostat signals when the system is off Block Er01 Safety error pressure control signals only if the combustion fan is turned on Block Er02 Shutt...

Страница 16: ...bmenu Combustion Management Combustion management Power In this sub menu it is possible to modify the system combustion power Use the P4 and P5 buttons to select from 5 powers Power 1 Power 2 Power 3...

Страница 17: ...the P1 button Disabled Daily Weekly Week End Chrono Program Chrono program provides three types of programming Daily weekly and weekend After entering the Chrono program the following message appears...

Страница 18: ...sible to choose between programs Mon Fri Sat Sun The selected programs will be active for the days from Monday to Friday or Saturday and Sunday The programs are activated and deactivated in the same w...

Страница 19: ...ue gas motor are active Ignition Fixed Phase This phase represents a fixed time period that lasts 180 seconds and in case the requirements for the ignition of the furnace are reached before the expira...

Страница 20: ...ge Er11 indicating that the DATE TIME is not accurate Deblock using the P1 button the value of TIME flashes signalling the need for updating the TIME and DATE with the function CLOCK 4 6 2 Pellet feed...

Страница 21: ...of pellet in the burning unit is too low or too high Wait for the furnace to extinguish and then press and hold P2 button for more than 3 seconds Check the size of the pellet Check the cleanliness of...

Страница 22: ...not achieved The presence of some large obstacle or debris in the pipe for entry of primary air Wait for the furnace to extinguish and then press and hold P2 button for more than 3 seconds Check and...

Страница 23: ...tenance of the furnace ATTENTION Each cleaning activity has to be performed when the furnace is completely cold and disconnected from the power supply with the cable pulled out from the socket Number...

Страница 24: ...ties Type 2 must be carried out at about 350 400 hours or else after about 500 600 kg of fuel ATTENTION Each cleaning activity has to be performed when the furnace is completely cold and disconnected...

Страница 25: ...can be removed These parts usually must be replaced every three years depending on the type of furnace the intensity of use etc Seals must be elastic at touch and must be replaced if they become tota...

Отзывы: