2. Preparation for Installation
112
2.4 Notes on electrical noise
Electrical noise emitted by other instruments can cause failures.
Note the following points when designing an electrical power equipment plan:
The branch circuit of a power supply to the Switch should not be accompanied with
devices or instruments that have a relay or micro switches to turn it on and off
repeatedly, such as air conditioners.
The service ground terminal of the device (Type D grounding) should directly
connect to the ground plate or, if possible, a dedicated ground system for the Switch.
As for the devices and the instruments emitting electrical noise, embed a circuit to
prevent noise generation.
The cables connected to the Switch are roughly categorized into power cables and
signal cables, which are basically different in electrical characteristics. Avoid banding
or twisting both types of cables when laying them.
Do not route the communication lines along the power cables.
Содержание AX2400S series
Страница 3: ...Copyright Copyright C 2005 2011 ALAXALA Networks Corporation All rights reserved ...
Страница 4: ......
Страница 6: ...Preface II Find description from the AX2400S series manuals ...
Страница 7: ...Preface III Find description from the AX3640S and AX3630S series manuals ...
Страница 10: ...Preface VI ...
Страница 14: ...Contents iv ...
Страница 160: ...3 Preparation of Interface Cables and Terminals 130 ...
Страница 214: ...4 Installation of the Components 184 ...
Страница 231: ...5 Expansion Replacement and Removal 201 Figure 5 18 Inserting the fan unit 1 Fan unit slot 2 Fan unit ...