Fluid Circulation Pump
©Aqua-Hot®
250-D03 Diesel Series Service Manual
REV 220302
p. 58
Burner Components
Flame Sensor Replacement:
1. In order to perform the following procedures, it is necessary
to detach the diesel burner head. Be sure to review the
detaching/reattaching instructions starting on Page 47.
2.
Remove the screw that fastens the flame sensor to the
photo disc (as shown in Figure 96), and detach the flame
sensor’s green and blue wires from the C-plug harness’
green and violet wires. Remove the defective flame sensor.
3.
Slide the tab of the new flame sensor into the provided slot
in the photo disc and secure in place with the screw.
4.
Connect the flame sensor’s green wire to the green C-plug
harness wire (pin 6), and connect the blue wire to the
C-plug harness’ violet wire (pin 4).
5. Follow the instructions for reattaching the diesel burner
head on Page 50.
Flame Sensor
Green Wire
Green Wire
(to Diesel Burner)
Photo Disc
Blue Wire
Violet Wire
(to Diesel Burner)
NOTE:
This screw is used to fasten the
Flame Sensor to the Photo Disc. Remove
when replacing the Flame Sensor.
Figure 95
Figure 96