Fluid Circulation Pump
©Aqua-Hot®
250-D03 Diesel Series Service Manual
REV 220302
p. 73
Instructions for Checking Fuel Pressure:
Step 1: Remove the diesel burner
Refer to the section on detaching the diesel burner on page 47.
NOTE:
A fuel pressure gauge is used to properly check the fuel pump’s pressure
setting. The fuel pump is preset to 145 PSI. Perform the following procedure to check
for a proper fuel pressure setting.
Step 2: Install the fuel line bypass fittings onto the diesel burner.
1. Locate the ¼” fuel tube unions on the bottom side of the
diesel burner.
2. Using a 13mm and a
9
/
16
” wrench, remove the steel fuel
lines from the diesel burner.
Figure 118
Figure 119
Figure 120
3. Using a 13mm and a
9
/
16
” wrench, install the fuel bypass
fittings onto the diesel burner.
Fuel Pressure