Controller
©Aqua-Hot®
250-D03 Diesel Series Service Manual
REV 220302
p. 9
250-D01 Switch Panel
Operating the Aqua-Hot
Operating the Aqua-Hot
Introduction:
This document will outline the basic operating instructions
for the Aqua-Hot using either the optional LCD Screen or the
coach LCD via the RV-C network communication. Contact your
coach manufacturer to determine which control panel you may
have. The screens will appear the same on either control panel.
Climate Pages:
The climate pages are for all intents and purposes the
“Home” of the display screen. From here, the end-user will select
their interior temperature set-points, activate or deactivate the
diesel burner and/or the electric element.
Zone Control (1):
Precise zone control display will differ depending on the type
of zone thermostats used within the coach.
Section 1A demonstrates the appearance of the zone control
section when ON/OFF thermostats are used within the coach.
In this use-case, these buttons serve only as ON/OFF toggle
switches.
Tapping on one of the zones shown above will display a new
screen where the interior temperature can be set.
A
B
C
Section A:
This section shows the current zone
temperature (shown as 71°F in the example
above) as well as a button to turn the zone
on or off. (Setting specific temperatures can
only be done
if thermistors are installed.
Thermostats would only show ON/OFF.)
If the zone temperature is set, but this item
is not set to ON, the zone heat exchanger will
not activate.
Section B:
These arrows are used to increase or decrease
the desired set-point temperature of the zone
thermistor.
Section C:
After the desired temperature set-point has
been selected tap “SET” on the display to set
that temperature. The Aqua-Hot will now work
to maintain this interior temperature, and the
screen will return home.
Diesel Burner Activation (2):
The diesel burner of the Aqua-Hot can be activated by
tapping on the “burner” item on-screen. The diesel burner has
two modes: ON and OFF.
ON:
While set to ON, the Aqua-Hot diesel burner will
work to maintain a tank temperature of 180°
F, with a minimum tank temperature of 160° F.
OFF:
While off, the diesel burner will not serve to
provide any heat to the boiler of the Aqua-Hot
whatsoever.
Electrical Element Activation (3):
Similar to the diesel burner, tapping this button will signal
to the controller to activate the AC electric relay, energizing the
1000W
electric element within the Aqua-Hot.
ON:
While set to ON, the electric element will work
to maintain a tank temperature of 180° F,
with a minimum tank temperature of 160° F.
OFF:
While off, the element will not serve to
provide any heat to the boiler of the Aqua-Hot
whatsoever.
1
3
4
5
2
1A
NOTE:
The Aqua-Hot LCD is an
OPTIONAL
add-on. It is
encouraged that RVs already equipped with an RV-C enabled
touchscreen have all Aqua-Hot screens and features
mirrored on the coach display.