Step 4: Remove the Diesel Burner
1. Locate the diesel burner’s controller and disconnect
both plugs.
2. Using a
7
/
16
” wrench, loosen the nuts securing each
fuel line to the Aqua-Hot.
3. The diesel burner is secured to the Aqua-Hot with two
nuts that can be loosened and swung out of the way
by using a 10mm socket wrench with a 10 inch long
extension.
Be sure to clamp off the fuel supply and return lines at
the ports on top of the Aqua-Hot PRIOR to beginning this
replacement procedure�
Disconnect both Diesel
Burner Controller Plugs
Figure 133
Figure 134
Step 1
Figure 135
Figure 136
Step 2
Burner Maintenance
Diesel Burner Controller
Step 3
Step 2