Fluid Circulation Pump
©Aqua-Hot®
250-D03 Diesel Series Service Manual
REV 220302
p. 51
Reattaching the Burner
Step 2: Reattach the fuel lines to the Aqua-Hot
Align the fuel lines on the diesel burner with the fittings on the Aqua-Hot, and using a
7
/
16
” wrench, tighten down both the supply
and return fuel fittings.
Be sure to remove the clamps off of the fuel supply and return lines
at the ports on the top of the Aqua-Hot prior to starting the diesel
burner, or serious damage will occur to the diesel burner’s fuel
pump�
Step 3: Reconnect the Controller and Mount
Locate the diesel burner’s Controller and connect both plugs that were previously disconnected.
Figure 79
NOTE:
The diesel burner’s Controller might have to be
mounted onto the side of the burner before the plugs
are inserted into the Controller, otherwise it might not be
possible to mount the Controller.
Figure 77
Figure 78
Figure 80
Diesel Burner Controller
NOTE:
Be sure to note the fuel line ports. The fuel ports on
a D03 product are reversed from the previous D01 products.
Diesel Fuel Return
Diesel Fuel Supply