I-66
G-084383_EN • 03
M
aintenance
Removing and Installing the Burner -
CM 60 - 70 - 80
Conditions:
î
Fan and air-gas mixer assembly removed, refer
to
“Removing and Installing the Fan and Air-
Gas Mixer Assembly” on page I-64
.
î
Electrodes removed, refer to
“Removing and
Installing the Ignition and Ionisation Elec
-
trodes” on page
I-63
Tools and material:
î
Wrench, hex head, size 4
î
Torque wrench
î
Air compressor
Removal Procedure:
Make sure that the ionisation electrode
is removed before removing the burner
door to prevent damaging the burner
door insulation (
6
).
1.
Release six hex head screws (
4
) securing the
burner door (
1
) to the combustion chamber.
2.
Remove the burner door (
1
) assembly (burn-
er door with gasket and burner tube).
3.
Turn assembly over and place carefully on a
flat and clean surface.
4.
Remove three screws and washers (
5
) to re-
move the burner tube (
3
) and gasket (
2
) from
the burner door. Discard the gasket (
2
).
Cleaning and Checks:
1.
Visually check the condition of the burner
tube (
3
).
2.
Clean with compressed air to remove residues.
If it is in bad condition after cleaning, replace it.
3.
If the combustion chamber requires clean-
ing, carefully remove burner door insulation
plate (
6
) from combustion chamber.
OFF
i
4.
Visually check the condition of the burner
door insulation plate (
6
). If the fabric cover is
damaged, replace the insulation plate.
5.
Clean the combustion chamber, see
“Check
-
ing and Cleaning the Combustion Cham
-
ber” on page
I-64
.
Installation procedure:
1.
Install burner tube (
3
) and new gasket (
2
) on
burner door (
1
) using three retained screws
and washers (
5
).
2.
If removed previously, install burner door in-
sulation (
6
) on burner door.
3.
Holding both the burner door (
1
) and the insula-
tion plate (
6
), position the burner door (
1
) on heat
exchanger.
4.
Tighten five hex head screws (
4
), then torque
in a crosswise pattern at 5 to 6 Nm.
5.
Follow-on tasks:
1.
Reinstall the fan and air-gas mixer assembly, re-
fer to
“Removing and Installing the Fan and
Air-Gas Mixer Assembly” on page I-64
.
2.
Reinstall the electrodes, as required. Refer to
“Removing and Installing the Ignition and
Ionisation Electrodes” on page I-63
.
3.
Reinstall all removed access panels, refer
to
“Removing and Installing the Access
Panels” on page I-31.
4.
Restart the appliance, see
“Restarting after
Maintenance” on page I-60
.
Содержание COILMASTER 100
Страница 67: ...X3 3 4 5 2 Fig 21 CM 60 70 80 Removing and Installing the Burner 1 6 I 67 G 084383_EN 03 Maintenance...
Страница 69: ...3 5 2 1 Fig 22 CM 100 120 Removing and Installing the Burner I 69 G 084383_EN 03 Maintenance...
Страница 92: ...I 92 G 084383_EN 03 Declaration of Conformity...
Страница 93: ...I 93 G 084383_EN 03 NOTES...
Страница 94: ...www myaic eu AIC Europe B V Graafschap Hornelaan 163A NL 6001 AC Weert The Netherlands...