Performance and Efficiency Data
CM 100
(min. - max.)
CM 120
(min. - max.)
heat input (net)
G20/G25
kW
12.5 - 99.0
12.5 - 115.0
G31
14.0 - 99.0
14.0 - 115.0
heat output at 80/60°C
G20/G25
kW
12.1 - 97.2
12.1 - 112.9
heat output at 50/30°C
G20/G25
kW
13.4 - 106.9
13.4 - 124.2
heating efficiency 80/60°C
G20/G25
%
97.5 - 97.8
97.5 - 97.9
heating efficiency 50/30°C
G20/G25
%
107.7 - 108.0
107.7 - 108.0
useful efficiency at 30% (return at 30°C)
%
108.2
108.2
seasonal efficiency
%
93.0
93.0
boiler type and model
CM 100
CM 120
condensing boiler
Y/N
Y
Y
low temp boiler
Y/N
Y
Y
combination heater
Y/N
Y
Y
useful heat output
at 30% of rated heat output (
P
1
)
kW
32.1
37.5
at rated output and high-temp regime (
P
4
)
kW
97.3
113.1
useful efficiency
at 30% of rated heat output (
η
1
)
%
97.5
97.5
at rated output and high-temp regime (
η
4
)
%
88.1
88.5
auxiliary electricity consumption
at full load (
elmax
)
kW
0.257
0.300
at part load (
elmin
)
kW
0.052
0.060
in standby mode (
P
SB
)
kW
0.003
0.003
standby heat loss (
P
stby
)
kW
0.30
0.30
sound power level indoors LWA
dB
55
55
seasonal space heating energy efficiency class
A
A
water heating efficiency class
A
A
declared load profile for water heating
XXL
XXL
Содержание COILMASTER 100
Страница 67: ...X3 3 4 5 2 Fig 21 CM 60 70 80 Removing and Installing the Burner 1 6 I 67 G 084383_EN 03 Maintenance...
Страница 69: ...3 5 2 1 Fig 22 CM 100 120 Removing and Installing the Burner I 69 G 084383_EN 03 Maintenance...
Страница 92: ...I 92 G 084383_EN 03 Declaration of Conformity...
Страница 93: ...I 93 G 084383_EN 03 NOTES...
Страница 94: ...www myaic eu AIC Europe B V Graafschap Hornelaan 163A NL 6001 AC Weert The Netherlands...