Presto Detacher
™
© 2012 AIC WAIKATO LLC
608-526-6882
28
Set-up Table:
All
Presto
Parlor
controls on the installation should be set-up the same. If Presto
Detachers are set-up via the Elite (See Elite set-up Instructions)
Function
Range
Increments
Factory
Settings
Effects of Adjustments
Review Data
Yes/No
Yes
Yes provides access to all
the data records in the
Presto Detacher
ID Enable
Yes/No
N/A
No
Presto Units will ask for an ID
number when starting milking
Language
N/A
English,
French,
German,
Spanish
English
Choose Language Displayed
Units of Measure
LB/F or Kg/C
LB/F
Change from Imperial to
Metric
Take-Off Flow
Rate
.2 to 4 LB/Min
.09 to 1.82 Kg/
Min
Varies
1.2
Increase to milk cows wetter
decrease to milk cows drier
Take-Off Delay
0 to 60
seconds
1 second
8 seconds
Increase to milk cows drier,
decrease to milk cows
wetter.
Max Milking Time 0 to 20 minutes
30 seconds
0 seconds Unit will detach after the
maximum time has expired.
Conductivity
Delay
0 to 3.9 LB
0 to 1.76 Kg
.1 LB
.4 Kg
3.5 LB
1.6 Kg
Increase to make less
sensitive, decrease to make
more sensitive
Milk Letdown
Delay
60 to 210
seconds
30 seconds
90
seconds
Increase for longer delay.
Allows to ignore low flow
rates at the beginning of
milking.
Retract Delay
0 to 10
seconds
.2 seconds
1 second
This delay allows for soft
take-off. The Presto control
shuts the vacuum off the
claw and then activates the
retraction cylinder in the
time this delay is set.
Pull Time
0-30 seconds
1 second
0
Always set a zero NOT
Used In Parlor
Sweep Delay
0 to 20
seconds
.5 seconds
0 seconds How long it takes for sweep
after detach
Sweep On Time
0 to 5 seconds
.2 seconds
0 seconds How long sweep occurs for