Overview

 

The Yieldpoint d-Exto is a multi-position (1-6) borehole extensometer or MPBX. It differs from traditional 
MPBX’s in that it arrives fully assembled and ready for installation. Typically, it is installed by grouting into a drill 
hole. The assembly consists of a series of groutable anchors attached to fiberglass rods. These rods are 
protected in Lexan tubing and terminate in a head assembly which integrates displacement transducers. 
Transducers are available in several ranges including 125mm, 150mm and 250mm. The transducers measure 
the relative movement between each anchor and the head assembly. These measurements provide for 
understanding deformation of the rock being monitored. 

The head assembly is usually installed at the collar of the drill, but can also be installed at the bottom of the drill 
hole. Measurements are then relative to the collar or the bottom, respectively, as illustrated below in Figure 1. 

 

(Figure 1) 

Integrated to the head assembly are electronics to read each displacement transducer and convert it to a digital 
format. A typical measurement response is shown below. 

:YP,160341050,d3EXTO,41,+ 19.9,C, 16.12,mm, 16.96,mm, 16.78,mm, <CR><LF> 

The head assembly also includes a RS-485 half-duplex (2-wire) interface for transmitting the digital string over 
long distances. A two-wire RS-485 interface is utilized.  

System wiring is detailed in the following section.  

Содержание Yieldpoint d-Exto MPBX

Страница 1: ...several ranges including 125mm 150mm and 250mm The transducers measure the relative movement between each anchor and the head assembly These measurements provide for understanding deformation of the...

Страница 2: ...ure 2 outlines connecting a d Exto to a Campbell Scientific CR1000 using the RSCOM2A converter from RE Smith The RSCOM2A provides a low cost highly configurable signal converter Figure 2 Note Two of t...

Страница 3: ...t the serial cable from the RSCOM2A to a computer using a straight through serial cable Launch a terminal emulation program such as HyperTerminal on the computer Configure the port to match the physic...

Страница 4: ...e d Exto nodes cannot use the same cable for communications Separate RS 485 RS 232 adaptors and separate COM port connections are required for each d Exto This limits the number of sensors that can be...

Страница 5: ...nfiguration form Note the Gage Type Make Model selection for Channel 1 The Units Conversion may also be used to convert the units The default output of the d Exto is millimeters Figure 7 To read the t...

Страница 6: ...onfiguration simply acts as a placeholder for the measurements Use the Multiplexers button on the Program tab to display the Configure Multiplexers form Select Virtual as the Model and Digital as the...

Страница 7: ...ar for Direct Connect configuration An example for channel 1 is shown in Figure 11 Figure 11 Once all channels are configured press Start Update to create the MCU program download it and start the Mon...

Отзывы: