Set-up Table:
All
Presto
Parlor
controls on the installation should be set-up the same. If Presto
Detachers are set-up via the Elite (See Elite set-up Instructions)
Function
Range
Increments
Factory
Settings
Effects of Adjustments
Claw Drop Delay
0.0 to 10.0
seconds
0.5 seconds
0.0
seconds
Delay after sweep to drop
claw.
Vacuum On
Delay
0.0 to 2.5
seconds
0.5 seconds
1 second
Delay to apply vacuum after
releasing cylinder
Claw Lift Enabled
Yes/No/Prep
Timer
No
Automatic claw lift with Herd
Tracker
Kick Off Detect
Time
0 - 5 Seconds
.2
0
Zero shut’s off the Kick-Off
feature any number turns
on. Increase to make kick-off
less sensitive, decrease to
make more sensitive.
Kick-Off Temp
Drop
.5 - 10 Degrees
F
.1 Degrees F
0
Decrease to make Kick off
feature more sensitive
Increase to make less
sensitive.
Make Meters
Read Higher or
Lower
-
15 to 15
1
+ 4
Increase to make the ’s yield
reader lower, Decrease to
read higher
Conductivity
Sensitivity Offset
-
30 to 30
1
+ 18
Increase to make less
sensitive, decrease to make
more sensitive
Milk Yield -
Percent
Compensation
-
25 to + 25 %
1
0
Milk Yield Compensation:
Increasing will make the
meter read more, decreasing
will make it read less.
Use CT Logic
(Software version
1.64 and later)
Yes/No
Yes
Yes enables CT Critical
Temperature Logic, no skips
CT logic and reverts to a
fixed temperature alarm.
Fixed Temp.
Alarm ONLY
USED WHEN IN
CT IS OFF OR
SWITCHED TO
NO
100-108 F
37.7 to 42.2 C
.2 Degrees
.1 Degrees
102.6 F
39.2 C
Adjust fixed milk temperature
alarm threshold.