Trimble Rate and Section Control Module
18 Pin Connector
•
Connects to Trimble Harness back
to in cab display
30 Pin Connector
•
This harness connects to the AgXcel
integration harness P/N - 53519
Common Troubleshooting Guidelines:
PWM Signal to Pump:
Pins E1 to E2 should have 0-12 volts to turn pump on.
Use manual mode to increase signal. Should get up to
12 volts after holding increase button.
Flow meter Tap Test:
Pins C2 and C3 are Flow Ground and Signal. If no flow
is registering on the display, you can tap between these
two pins with a short wire. This produces a pulse. The
display should indicate a flow when this is done rapidly.