www.agxcel.com
16
Pump Priming and Bleeder Valve
AgXcel’s Micro Control Valve
AgXcel’s micro control valves are designed to eliminate the need for
large sectional valves. The small compact design makes them ideal for
controlling flow through the manifolds.
Implements that are 60 ft and wider may be set up with 2 control valves,
therefore half of the applicator can be shut off. These systems are setup
similar to a single section setup. However, Section 1 of the boom harness
will connect to one valve and Section 2 will connect to the other valve.
Please note, implements that are less than 60 feet wide need to be
setup as one section on order to prevent range dropping below flow
meter capabilities at lower speeds.
A bleeder valve is included on every AgXcel system.
Every row has a check valve. These valves do not let
air escape from the system unless it is pressurized.
12 volt electric pump are not good air compressors,
so pumps can struggle to prime due to air trapped
on the outlet side of the pump.
The bleeder valve is a small 1/4” valve that, when
opened, lets air escape from the pump outlet at
zero pressure. Open this valve until liquid comes
out and then close the valve.
Bleeder Valve
AgXcel’s micro control valve (MCV) includes an
indicator light. The red light shows voltage/power
being supplied to the valve. It will turn Green
when receiving a signal to open/close.
GX40 PRO STOP COMPLETE
REPLACEMENT BODY
PN# 709