AgXcel’s Mag Flow Meter
0.08 - 1.6 GPM
AgXcel’s Magnetic Flow Meters are superior to turbine flow
meters in two ways. Magnetic flow meters have no moving
parts. This eliminates any wear items or any potential for
contaminants to jam a spinning turbine.
In addition, magnetic flow meters detect flow by electrically
measuring the velocity of the liquid which make them inde-
pendent of viscosity or density of the liquid measured. While
extremely accurate when using the indicated calibration
number, AgXcel strongly recommends performing a catch
test to verify the system is properly installed and configured.
The flow meter included with your Synergist system is rated
down to 10 oz/min, but will accurately measure flow down
to 8 oz/min. Anything below 8 oz and the flow meter may
not give a continuous pulse output.
Caution: Before welding on the implement, disconnect the
flow meter or damage to the flow meter electronics may
occur.
Do not power wash the flow meter. High pressure spray directed at the back edge of the face plate or at the
wire connector may allow water into the flow meter electronics.
Pressure Sensor
The GX40 Synergist comes equipped with a 100 psi pres-
sure sensor to work with your controller. The sensor for
the rate controller is a 3-wire type sensor. The Sensor has
a 1/4” MPT fitting.
Your display will show the system pressure on the in cab
screen.
The pressure reading is only for informational
purposes and is not used in the flow control process.
Flow control uses the flowmeter feedback only.
The pressure sensor is very helpful to optimize system
performance and troubleshoot any issues.
The pressure transducer is factory calibrated and will
display a very accurate pressure reading on your display.
No manual gauge is required. However, the Synergist will
have a visual gauge for quick reference when standing
near the system and not in cab to see controller display.
When attaching connector to pressure sensor, make sure
pins are aligned so they are not bent.
396
-
29
74
Y1
SureF
ire
C
a
ta
ly
st
™
for Nutr
iS
phe
re
®
-
N NH3
& J
oh
n De
ere
7
Re
vi
se
d 0
3/16
/20
16
The
T
ow
er 10
0
co
mes
eq
ui
pp
ed
w
ith
a
10
0 ps
i p
res
su
re
se
ns
or
to
w
ork
w
ith
you
r co
nt
rol
ler
.
Thi
s sen
sor
fo
r t
he
Joh
n
D
ee
re
Ra
te
C
on
trol
ler
is a
3
-
w
ire
ty
pe
sen
so
r.
Th
e
Co
m
m
an
de
r I
I
use
s
a 2
-
w
ire sensor
. T
he sensor
ha
s
a
1/
4”
M
PT
fit
tin
g.
You
r di
spl
ay
w
ill sho
w
the
sy
st
em
pres
sure
on
th
e
in
cab
scr
ee
n.
The
pres
su
re read
ing
is
only
for i
nf
or
mat
ion
al
pu
rpos
es
an
d
is
NO
T us
ed
in
the
fl
ow
co
nt
ro
l proc
es
s.
Fl
ow
c
on
tr
ol
u
ses
th
e
flo
w
m
et
er
fee
db
ac
k o
nl
y.
The
pressu
re
sen
sor
is v
ery
he
lpf
ul
to
op
tim
iz
e
sy
st
em
pe
rfor
m
an
ce
an
d
trou
bl
esh
oo
t an
y i
ssue
s.
The
pressu
re
tran
sdu
cer
is
fa
ct
or
y cal
ibrat
ed
an
d
w
ill di
spl
ay
a
very
accu
rate
pressure
rea
di
ng
on
you
r di
spl
ay
. N
o
m
an
ua
l g
au
ge
is r
eq
ui
red
.
W
hen
a
ttac
hi
ng
co
nn
ec
tor
to
pr
es
su
re
se
ns
or
, m
ak
e
sure
pi
ns
a
re
al
ign
ed
so
the
y
are no
t be
nt
.
Pressure S
ensor
B
Com
po
ne
nts
Liq
uid
Pr
es
sure S
en
sor (
3
wi
re
ty
pe)
w
ith h
ar
ne
ss
521
-
05
-
050
150
Pum
p P
rim
ing and
Air B
leed
Val
ve
An ai
r bl
ee
d v
al
ve is in
cl
ud
ed
w
ith each pu
m
p
to
ai
d in
sy
st
em
primin
g.
It
is
shi
pp
ed
in t
he
pu
m
p a
ccesso
ries
ba
g
and
m
ust
be
instal
led
du
rin
g sy
st
em
ins
tal
latio
n.
W
hy
us
e
an
ai
r bleed
v
alv
e:
You
r sy
st
em
is e
qui
pp
ed
w
ith
a
4
lb
. che
ck v
al
ve
on
ea
ch
m
ete
rin
g
tub
e.
T
he
se
v
al
ves
do
no
t l
et
a
ir
esca
pe
fr
om
the
sy
st
em
un
less
it
is
pressu
riz
ed
.
12
v
ol
t l
iq
ui
d
pu
m
ps
ar
e
no
t g
oo
d ai
r c
om
pr
esso
rs.
The
re
fo
re,
the
pu
m
p can
st
ru
gg
le
to
pri
m
e
due
to
ai
r t
rap
pe
d
on
the
ou
tle
t si
de
o
f t
he
pu
m
p.
The
ai
r bl
ee
d v
al
ve is a
sm
al
l
1/4”
val
ve t
ha
t w
he
n
op
en
ed
lets
ai
r esc
ap
e
from
the
pu
m
p
outle
t at
zero pressu
re.
O
pe
n un
til
li
qui
d
co
m
es
ou
t an
d
the
n
clo
se
the
v
al
ve.
Ho
w
to
ins
ta
ll t
he
ai
r b
lee
d
valv
e:
R
em
ov
e t
he
1/
4”
pl
ug
fr
om
the
q
ui
ck
con
ne
ct
fi
tti
ng
on
the
cen
te
r cr
oss
on
th
e
Tow
er
(see
pi
ct
ure
).
N
ex
t, i
ns
ert
the
1/
4”
tub
ing
in
the
q
ui
ck
co
nn
ec
t
fitti
ng
. R
un
th
e
1/4
”
tub
ing
to
an
ea
si
ly
acce
ssi
bl
e
spo
t on
y
ou
r e
qui
pm
en
t.
N
ex
t, cu
t t
he
tub
in
g an
d
pu
sh t
he
1/4
”
val
ve
ont
o
the
tub
ing
.
Fi
na
lly
, r
un
the
tub
ing
to
a
lo
w
loca
tion
w
he
re
any
product
tha
t
esca
pe
s w
ill r
un
on
the
ground
.
B
e
sure
the
a
ir bleed
v
alve
tub
e
doe
s no
t
be
co
m
e
pl
ug
ge
d
w
ith
di
rt
or
it
w
ill
no
t a
llo
w
a
ir
to b
lee
d.
1/4
”
Tu
bin
g
1/4
”
ai
r bl
ee
d v
al
ve
3
-
w
ire s
ens
or
Pre
ss
ure C
alib
rat
ion:
50 m
v/
ps
i
Shi
pp
ed
fro
m
fac
tor
y
wi
th pl
ug
in
st
alle
d.
PN #53491
Содержание Synergist GX40 System
Страница 36: ......