Pumps run for a few seconds then turn off

This symptom is due to the pumps drawing more current than the 40 amp limit of the EPD.

1. Unplug the EPD

 connector going to the battery for 2-3 seconds. Removing power from the EPD resets it.

2. Go to Diagnostics

, Section Test to investigate this issue.

3. In Section Test

, hold down “+” button for a few seconds. A single tap of this button produces a very 

small change in signal to the valve, so you must hold it.

4. Increase the flow slowly, checking the “1,2,3” screen to see you flow in GPM. Find the approximate flow 

where the EPD kicks out. If this is below the flow you need you will need to reduce system pressure by:

• 

Looking for any unintended restrictions or plugged rows

• 

Increase orifice size

• 

Reduce ground speed

• 

Reduce application rate

Electric pumps will not turn on

Connect pumps directly to battery

1. Find the EPD (electric pump driver) shown at right. 

Connect  the  two  connectors  (

highlighted  green, 

shown on the right

) to each other. This will bypass 

the module and supply 12 volts directly to pumps.

2. Do the pumps run? If not, check the 40 amp fuse 

on the EPD harness that is connected to the trac-

tor  battery.  Inspect  harnesses  and  connections. 

Make  sure  wire  colors  match  up.  (white/white, 

black/black)

3. If using a dual pump system, test each pump by 

plugging one pump at a time directly to the bat-

tery. 

PWM Signal

To Pumps

Power from

Battery

Inspect connections for burned out connectors.

Inspect all connections for bent or burned out leads. Constantly running the system at a 

high pressure or getting more than the required voltage (12v) can result in burned out 

connections causing the system to not work properly. 

TROUBLESHOOTING

(Read Instructions Completely before Beginning Installation)

Содержание Synergist GX40 System

Страница 1: ...om AUTOMATIC RATE CONTROLLER reference manual Low Volume System for IntegrationintotheTrimble NOTE This is only a guide Please consult your Trimble dealer for detailed instructions or troubleshooting...

Страница 2: ...re greatly reduced By using a Dual Micro tube Solution two micro tubes the system will be able to handle a variety of rates and speeds As well as handling a wide range of temperature changes that woul...

Страница 3: ...contains information and settings for AgXcel s Synergist system for NutriSphere N NH3 Changes to components or configuration settings can be made to improve operation of the system Below are some bas...

Страница 4: ...The harness coming out of the Trimble rate controller is a 30 pin amp connector that will be connected to the AgXcel 30 pin cinch con nector extending from the AgXcel GX system Trimble Harness F AgXce...

Страница 5: ...integration harness P N 53519 Common Troubleshooting Guidelines PWM Signal to Pump Pins E1 to E2 should have 0 12 volts to turn pump on Use manual mode to increase signal Should get up to 12 volts af...

Страница 6: ...How ever the 750 has a completely different screen layout and menu structure that is not shown in this manual Use your Trimble manual to navigate then enter the appropriate num bers from the AgXcel m...

Страница 7: ...er controls the speed at which the valve increases or decreases when you press the Rate Adjustment Switch on the Master Switch Box Minimum Rate is typically set at 0 Maximum Rate is set at something h...

Страница 8: ...you can select and or edit Setup Control Material Select your desired material from the Available Materials Layout From the Layout screen you can enter a Location Name such as Front Tank Rear Tank et...

Страница 9: ...s Serial Number Set the number of Sections for your system Press Section Widths Set the widths of your sections Press the Setup button next to Section Control to take you to the Section Control Setup...

Страница 10: ...lve Disabled OPTIONAL If using an Aux Dump valve to keep the pump run ning when application stops so the system will resume applying at the Target Rate immediately upon restart set Auxiliary Valve to...

Страница 11: ...dule that is controlling this sensor REMINDER The pressure sensor is for informational purpos es only and does not control the system in any way To finish the Pressure Sensor setup it will be necessar...

Страница 12: ...ment Setup is where you set the information for the implement you are using Mainly these settings affect the guidance control However if using auto section shutoff these settings will determine when e...

Страница 13: ...e Tuning page set the settings as shown Upper PWM Limit 100 Lower PWM Limit GX5 hydraulic 28 GX2 electric 0 Synergist 0 Integral Gain Adjust as needed GX5 hydraulic 10 GX2 electric 15 Synergist 100 Mi...

Страница 14: ...will need a stop watch to measure time AgXcel recommends running the test for some duration in minutes for simple math When your containers are in position under multiple fertilizer outlets press the...

Страница 15: ...e buttons increase decrease flow Move Switch 2 to rate 1 and set speed to your typical field speed The system should begin to pump liquid now in automatic control mode Is the flow in GPM stable Is it...

Страница 16: ...need to be setup as one section on order to prevent range dropping below flow meter capabilities at lower speeds A bleeder valve is included on every AgXcel system Every row has a check valve These va...

Страница 17: ...Fire Catalyst for NutriSphere N NH3 John Deere 7 Revised 03 16 2016 The Tower 100 comes equipped with a 100 psi pressure sensor to work with your controller This sensor for the John Deere Rate Control...

Страница 18: ...s Completely before Beginning Installation EPD LED Signals AgXcel has 2 styles for EPD s One of the models has three lights and the other model has five lights Ensure that you are looking at the corre...

Страница 19: ...ground speed Reduce application rate Electric pumps will not turn on Connect pumps directly to battery 1 Find the EPD electric pump driver shown at right Connect the two connectors highlighted green s...

Страница 20: ...ed above Auto X Accessories Whisker Run Hold Switch 1 3 2 whisker switch when red lead is connected to pole 1 and black lead is connected to pole 2 pumps will run when whisker is straight when red lea...

Страница 21: ...l that a fertilizer system is working These indicators use an o ring and wire clip connection to snap together in any configuration necessary The flow to each row will pass through a flow column that...

Страница 22: ...END CAP CLIP F 38260 GX1 CHASSIS TOMAHAWK ONLY G 18042 ISOLATED FEED H 32264 3 8 MNPT TO 3 8 HOSE BARB I 18033 3 8 HOSE SHANK 90 DEG 25682 LOCK U CLIP J 17701 GX1SHUTOFFBRACKET COMMON UBOLT S 17703 GX...

Страница 23: ...ed ball PN DESCRIPTION 55634 GX40 DUAL TUBING 12 FT SKY NAVY 55938 GX40 DUAL TUBING 12 FT GREY NAVY 38251 GXMT GREEN SOLD BY THE FT NOTE GX40 USES 4FT OF GREEN MT PER ROW 20121 1 4 PTC DIVIDER 55212 3...

Страница 24: ...rd kit Dual Navy Sky PN 55634 Situational and dependent on speed of implement 12 lengths per row are standard for the GX40 Synergist and included in all kits 1 4 QC SHUTOFF PN 19848 1 4 QC DIVIDER w M...

Страница 25: ...e The 4 green tube delivers the product to the shank 1 Slide a 2 piece of 3 8 hose over the green tube along with 2 clamps 2 Slide the green hose in the tube on the shank as far as it will go 3 Slide...

Страница 26: ...ginning Installation TANK AGITATION RINSE TANK PRODUCT FERTILIZER TANK INLINE 1 CHECK VALVE 3 WAY BALL VALVE BOTTOM OF PRODUCT TANK TANK AGITATION PRODUCT FERTILIZER TANK RINSE TANK RINSE TANK OUTLET...

Страница 27: ...E A C D D TANK AGITATION PLUMBING PN QTY ITEM F 32324 1 1 4X3 8 ELBOW HOSE BARB G 32433 1 3 4X1 4 REDUCER H 52169 1 2 WAY BALL VALVE I 32399 1 3 4 THREADED NIPPLE J 52146 1 3 4 X 90D ELBOW RINSE TANK...

Страница 28: ...get your implement information at ordering time to make sure that all of the hardware needed for your system is included ITEM PN DESCRIPTION C 55625 GX40_LOWPROFILEBARMOUNT 53719 9 BOLTS 5 8 38402 5 8...

Страница 29: ...1 4 CAP QC 1 37614 WILGER LOW FLOW COLUMN 1 262 QC3 1 4 TO 1 4 QC 4 55212 1 3 IN LINE CHECK VALVE 2 38412 SST 6 CLAMPS 2 55938 GX6MT DUAL NAVY GREY 12FT 2R 37721 1 4 DIVIDER WITH MOUNT HOLE 2 20121 1...

Страница 30: ...LOWMETER On the magnetic flowmeter there will be a sticker located on one of the sides Find the pulses per gallon and use the chart in your OEM manual to determine your flowmeter calibration number Wh...

Страница 31: ...will typically operate with the recirculation valve closed The metering tube on the recirculation loop can be changed to allow for more or less recirculation Too much recirculation can result in unst...

Страница 32: ...ycled motor may cause an explosion DO NOT assume fluid compatibility If the fluid is improp erly matched to the pump s elastomers a leak may occur Pumps used to transfer hazardous or hot max tempera t...

Страница 33: ...cally 15 20 psi 1 1 4 bar less than the shut off pressure the switch will close and the pump will operate until the shut off high pressure is achieved The shut off pressure is set to factory calibrate...

Страница 34: ...and correct voltage at switch or motor wires as equipped Check rectifier or motor for open or grounded circuit Check for locked drive assembly Pump will not prime Check to see if out of product no di...

Страница 35: ...ler If the part is not in working order it will be discarded unless you request that it be returned to you RETURNS AgXcel will gladly accept returns for new items purchased directly from us if returne...

Страница 36: ......

Отзывы: