31
877.218.1981
Revised09.2018R1
GX ACCESSORY - RECIRCULATION KIT
(Read Instructions Completely before Beginning Installation)
APPLICATIONS
1. Recirculation flow is required for product agitation.
2. IF a low flow rate is required, that would require pump to run
less than 10-20% of maximum capacity. This kit will allow the
pump to turn faster, while only applying a low rate of product.
This makes the pump performance more stable under these
circumstances. Make sure the flowmeter minimum flow is capa-
ble of metering the flow rate you wish to apply to the ground.
HOW IT WORKS
The recirculation valve diverts some pump flow before the flow-
meter. The application rate is still measured by the flowmeter and
everything that passes through the flowmeter is applied to the
ground. Adjust the regulation valve to set the required recircula-
tion.
USE OF THIS KIT LOWERS THE MAXIMUM RATE THAT CAN BE APPLIED
Do I need recirculation flow?
Recirculation flow allows the pump to run faster than if the total pump
flow was applied to the ground. This may be helpful when operating at
very low rates. The Synergist will typically operate with the recirculation
valve closed. The metering tube on the recirculation loop can be changed
to allow for more or less recirculation. Too much recirculation can result
in unstable flow reading on the display.
Recirculation Regulation Valve
RECOMMENDED CARE AND MAINTENANCE
(Read Instructions Completely before Beginning Installation)
WINTERIZATION
AgXcel recommends flushing your fertilizer pump and complete system with adequate amounts of water first.
Next, use RV antifreeze to winterize your system by pumping an adequate amount through all components.
RECOMMENDED PRESSURE (GX ELECTRIC SYSTEMS ONLY)
Agxcel recommends to maintain a pressure between 10 and 20 psi. Doing so, and with proper winterization, will
ensure the durability of the system, and reduce problems when preparing for the next season.
TESTING THE SYSTEM
Agxcel recommends testing your system with water first. Water testing will help determine if the plumbing and
hardware is secure.
CALLING FOR TECH SUPPORT
Before calling for tech support, please check our troubleshooting section. If your problem cannot not be re-
solved please have your serial number handy so our technicians can easily look up your order. Serial numbers
can be located on the chassis of the pump systems, or on the front page on the installation guide.