Initial Operation Instructions
AgXcel highly recommends you perform these exact steps with water to verify system is correctly installed
and ready for field use.
• From the
Configuration Screen
, select
Field-IQ
, then
Diagnostics
. (If the Diagnostics tab is grayed out, you
probably need to close a Field)
•
Make sure that your pump is ready to be tested. Raise the implement and then tap
Next
• Press the
+
next to
Speed
to simulate a
Speed
signal.
• Turn the
Field-IQ
master switch (#5)
On
.
•
Push each section valve button and verify each valve is
working.
• Turn
Switch #2
to
Manual
and open the section valves. Use
Switch #1
to increase flow. Does “
Current Flow
” display a
flow rate? Is it stable after the system is primed? Do the
increase & decrease buttons increase & decrease flow?
• Move
Switch #2
to
rate 1
and set speed to your typical
field speed.
•
The system should begin to pump liquid now in automatic
control mode.
Is the flow in GPM stable? Is it applying the
correct rate? (applied rate = target rate?)
•
Change rate using screen buttons or switch #1 to increase/
decrease rate or switch #2 to go to rate 2.
Does applied
rate change to equal target?
•
Close 1 section valve, does flow decrease? Does applied
rate still equal target rate?
•
Change speed and target rate to minimum and maximum
values.
Does the system perform at these values? Does the
system pressure seem reasonable (remember fertilizer will increase pressure over water)?
Use “Sensor”
tab at the top of the page to read pressure sensor value (If equipped).
Running the System with water will create much lower pressure than fertilizer.