On the Calibration page, select
Field-IQ
then
press Calibrate button
•
This will bring you to the Field-IQ Configuration
screen
• Select
Drive Calibration
• You can leave
Maximum Flow
set to 0 or enter
the
Maximum Flow
rate of your pump in Gal/
Min. Then press Next
•
Follow the screen instructions to run
Auto Tun-
ing
procedure.
• Press
Next
at the bottom of the screen to go to
the
Drive Settings
.
•
The settings on the
Drive Settings
screen are all
duplicated on the
Advanced Parameters
screen.
Press the
Advanced Parameters
button to go to
the next screen.
• On the
Advance Tuning
page, set the settings as
shown:
•
Upper PWM Limit:
100
Lower PWM Limit:
GX5 (hydraulic)……………28
GX2 (electric)………………0
Synergist…………………….0
Integral Gain: (Adjust as needed)
GX5 (hydraulic)……………10
GX2 (electric)………………15
Synergist…………………….100
Minimum Response: (Adjust as needed)
GX5 (hydraulic)……………20%
GX2……………………………..0%
Synergist……………………..5%
Allowable Error:
GX5 (hydraulic)……………1%-3%
GX2……………………………..3%
Synergist……………………..5%
Smoothing Factor:
GX5 (hydraulic)……………1%-3%
GX2……………………………..3%
Synergist……………………..1%
Field IQ Calibration
NOTE
: The TMX-2050
will use Proportional
Gain instead of the In
-
tegral Gain. This is the
opposite of the FmX.
The Auto Tuning pro
-
cess should set this. If
not, start with Propor-
tional Gain at 20-30.
Quick Start Setup Instructions for Trimble’s FM
750, FM1000, FMX Rate Controller
GX40 Synergist .... 0
GX40 Synergist .... 100
GX40 Synergist .... 5%
GX40 Synergist .... 5%
GX40 Synergist .... 1%
AGXCEL INTEGRATION INTO THE TRIMBLE
(Read Instructions Completely before Beginning Installation)