(see Display 19) will no longer restrict the view to the reports matching
that filter criterion.
5.3.1 Viewing the Full Welding Report
The full welding report can be viewed after touching the
button in
the extended report viewer. From the ambient temperature during the
welding operation to the assessment by visual check, taking in all force
and time values measured in the process and the previously entered
traceability data, this detailed view of the report features every single
technical information that is relevant for the joint.
5.3.2 Ongoing Job Reporting Scheme and Statistical Overview
Since all welding operations are recorded at any
rate in an ongoing approach, a statistical over-
view of the welding operation is available. To
open it, touch the
button in the extended
report viewer (Display 20).
The next screen is a menu allowing to select
whether the number of weldings per week, with
components of a certain diameter, material, with
error/malfunction, or the standard statistics with
number of flawed and proper weldings and total
number of welding operations with the machine
and currently in memory will be displayed. To
select the desired menu option, touch the
button next to it.
Die statistical overview is presented as a bar chart, where the extreme
values are color-coded.
The view filters of the extended report viewer can be used (see at the
beginning of Sect. 5.3 above). If they are used, the project/commission
and/or welder for which the number of weldings by a given criterion is
displayed in the bar chart, are the ones previously set in the settings of
the report viewer.
5.4 Deleting Reports from Memory
To delete the reports stored in memory, use the appropriate option in the
extended set of parameters in the configuration menu (see Sect. 4.2).
Upon touching this button, two safety warnings asking if you really want
to delete them appear on the screen and have to be confirmed to effec-
tively delete the reports currently in memory.
6
System Data
6.1 System and Maintenance Information
The home screen (Display 3) allows access to
system data (control software version, service
and maintenance contact, etc.), which may be
requested by the manufacturer or seller in case
of malfunctions, as well as to information on the
last and next preventative maintenance of the ma-
chine. To access the data, touch the
button.
6.2 Enabling Automatic Heating
When the “Automatic Heating” sub-menu was selected in the configura-
tion menu (see sub-section 4.2), the screen shows what is reproduced
in Display 24.