4.9 Aborted Welding Process
All welding-relevant data are constantly moni-
tored while the welding process is running. If one
or more of the parameters are out of tolerance
and the machine cannot adjust them, the welding
process is aborted after a given period of time.
The error that made the welding abort is dis-
played on the screen (see Display 17), for most
of them only as soon as the heating element is
taken away from the machine.
Type of Error
Description
a. Data Input
Input Error
Error while entering data on the touchscreen.
Code Error
Error while reading data from a transponder card.
RTC Error
The sender/receiver does not work properly. The error
message may also be about whether reading or writing
data is flawed.
b. System
System Error
Malfunction in the control system of the machine; power
to the machine has to be turned off and unplugged
immediately, and the machine has to be sent to the
manufacturer or an authorized service point for check
and repair.
Motor not Found
The initialization of the servo-motor that moves the
mechanical structure has failed.
Proximity Switch Error
A malfunction in the proximity switch having already
been energized at the start of zeroing the position of
the movable carriage.
Printer not Ready
The printer or USB stick connected to the machine is
not ready (no communication or faulty cable).
Error of Memory
If “empty” error: despite no report in memory, download
was started; if “full” error: there are no more unused
slots for reports, and memory control is enabled.
No Function Available
A control (key, button) was used for which no function is
defined.
Welder Code Expired
The welder identification code is no longer valid.
c. Welding Process
Temperature above
Maximum
The heating element temperature is higher than allowed
before the facing process.
Welding Aborted
Welding Stopped
The process was aborted by pressing the emergency
stop or by the control system or stopped by the welder.
No Extra Material
In a welding process that requires an additional
(“extra”) material, no such material was entered.
Facing Distance Error
The distance the carriage travelled at facing is too short
or too ling; welding has to be repeated.
Excessive Force Error
The applied force is out of tolerance; welding has to be
repeated.
Excessive Motor Current
Servo-motor Error
When moving the mechanical chassis, the motor drew
excessive current; welding must be repeated. When
welding is done, this error is called Servo-motor Error
Display 17