![Agilent Technologies auroraSonata Скачать руководство пользователя страница 290](http://html1.mh-extra.com/html/agilent-technologies/aurorasonata/aurorasonata_user-manual_2868636290.webp)
aurora
Sonata
Hand Held ISDN Tester—User Guide
A2-6
427869
86
Call having the requested call identity has been cleared
The network has received a Call Resume request for a call ID
which once corresponded with a suspended call, but the call
was cleared while still suspended. It may have been cleared
either by the network timing out or by a remote user.
88
Incompatible destination
The equipment has received a request to establish a call to a
destination which cannot handle the required compatibility
attributes (e.g. data rate).
91
Invalid transit network selection
95
Invalid message, unspecified
This cause is used to report that a message is invalid, only
when no other cause in the ‘invalid message’ class applies.
96
Mandatory information element is missing
The equipment has received a message with one or more
mandatory information elements missing, and therefore cannot
process the message.
97
Message type non-existent or not implemented
The equipment has received a message of a type it does not
recognise, either because the message is undefined or because
it is not implemented by the equipment.
98
Message not compatible with call state, or message type
non-existent or not implemented
The equipment has received a message which it considers to be
not permissible while in the call state; or a Status message that
indicates an incompatible call state.
99
Information element non-existent or not implemented
The equipment has received a message containing an
information element which is not recognised; either because
its ID is not defined or because it is not implemented by the
equipment. However, the equipment can still process the
message without the information element.
100
Invalid information element contents
The equipment has received an information element which it
has implemented. However, the contents are incorrectly coded
(e.g. truncated, invalid extension bit, invalid field values, etc.).
Содержание auroraSonata
Страница 2: ...auroraSonata Hand Held ISDN Tester User Guide 427869...
Страница 4: ...auroraSonata Hand Held ISDN Tester User Guide ii 427869...
Страница 26: ...auroraSonata Hand Held ISDN Tester User Guide 1 18 427869...
Страница 110: ...auroraSonata Hand Held ISDN Tester User Guide 3 64 427869...
Страница 147: ...Issue 2 07 00 4 37 Testing in Simulation Mode Section 2 3 Select the test option you require...
Страница 194: ...auroraSonata Hand Held ISDN Tester User Guide 4 84 427869...
Страница 208: ...auroraSonata Hand Held ISDN Tester User Guide 5 14 427869...
Страница 230: ...auroraSonata Hand Held ISDN Tester User Guide 6 22 427869...
Страница 260: ...auroraSonata Hand Held ISDN Tester User Guide 7 30 427869...
Страница 261: ...Issue 2 07 00 8 1 Power Sources Chapter 8 Power Sources Contents Using external mains power 8 2 Using battery power 8 3...
Страница 280: ...auroraSonata Hand Held ISDN Tester User Guide 9 12 427869...
Страница 281: ...Issue 2 07 00 A1 1 Appendix 1 Menus Appendix 1 auroraSonata Menus...
Страница 284: ...auroraSonata Hand Held ISDN Tester User Guide A1 4 427869 Setup General...
Страница 285: ...Issue 2 07 00 A2 1 Appendix 2 Disconnection Clearing Error Codes Appendix 2 Disconnection Clearing Error Codes...
Страница 296: ...auroraSonata Hand Held ISDN Tester User Guide A2 12 427869...
Страница 297: ...Issue 2 07 00 A3 1 Appendix 3 Introduction to ISDN Appendix 3 Introduction to ISDN...
Страница 309: ...Issue 2 07 00 A4 1 Appendix 4 Glossary Abbreviations Appendix 4 Glossary Abbreviations...
Страница 321: ...Issue 2 07 00 Index 1 Index Index...
Страница 336: ...auroraSonata Hand Held ISDN Tester User Guide Index 16 427869...