4349B
Trigger
K
ey
The
Trigger
key
triggers
a
measurement
in
manual
trigger
mode
.
Local
K
ey
The
Local
key
returns
the
4349B
to
the
local
mode
(front-panel)
operation
from
the
GPIB
remote
mode
(computer
controlled).
When
the
4349B
in
the
remote
mode
,
the
Rmt
annunciator(
9
)
will
be
displayed.
A
ddress
K
ey
The
A
ddress
key
sets
the
4349B 's
GPIB
address
.
The
available
GPIB
addresses
are
the
integer
numbers
0
to
30.
A
ddress
31
is
the
talk
only
mode
in
which
the
4349B
sends
data
through
GPIB
interface
.
In
the
talk
only
mode
,
the
output
data
is
,
<stat1>,<data1>,< comp1>,<stat2> ,<data2>,<comp2 >,<stat3>,< data3>,<comp3> ,
<stat4>,<data4>,< comp4>
Where
,
<stat1-4>
measurement
status
of
each
channel
0
:
normal
1
:
overload
2
:
no-contact
<data1-4>
measurement
data
of
each
channel
<comp1-4>
comparison
result
of
each
channel
(no
output
when
the
comparator
function
is
OFF)
1
:
in
2
:
high
4
:
low
8
:
no-contact
The
system
reset
or
power-on
doesn't
aect
the
address
setting.
Trigger
Mode
K
ey
The
Trigger
mode
key
toggles
three
trigger
mode|
Internal,
Manual,
or
External.
The
4349B
also
has
another
trigger
mode
,
BUS.
Internal
(Int)
The
internal
trigger
mode
.
In
this
mode
measurements
are
free
running
and
continuous
.
(Default)
Manual
(Man)
The
manual
trigger
mode
.
In
this
mode
,
the
4349B
performs
a
single
measurement
when
the
front-panel
key
is
pressed.
External
(Ext)
The
external
trigger
mode
.
The
4349B
is
triggered
by
a
TTL
level
pulse
input
through
the
rear
panel
External
Trigger
connector
,
or
through
the
handler
interface
.
F
or
more
information,
refer
to
\External
Trigger".
Bus
This
mode
is
available
only
in
the
GPIB
remote
mode
.
In
this
mode
,
the
GET
command
and
*TRG
command
trigger
a
single
measurement.
3-6
Function
Reference
Содержание 4349B
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 8: ......
Страница 20: ......
Страница 29: ...C Overload No Contact Operations Messages Instrument Errors Messages 2 GPIB Errors Messages 3 Index Contents 9 ...
Страница 42: ...4349B Figure 1 1 Power Cable Supplied 1 10 Getting Started ...
Страница 66: ......
Страница 88: ......
Страница 104: ......
Страница 146: ......
Страница 160: ......
Страница 173: ...4349B Figure 8 5 Current Measurement Additional Error Measurement Time 400 msec General Information 8 11 ...
Страница 176: ...4349B Figure 8 9 10 Additional Error Measurement Time 400 msec 8 14 General Information ...
Страница 210: ...4349B Figure B 1 Handler Interface Comparison Output Signals Diagram B 2 Handler Interface Installation ...
Страница 212: ...4349B Figure B 3 Handler Interface Input Signal Diagram B 4 Handler Interface Installation ...
Страница 216: ...4349B Figure B 4 A1 Main Board B 8 Handler Interface Installation ...
Страница 228: ......