4349B
Front
P
anel
This
section
gives
a
guided
tour
of
the
front
panel.
F
or
a
detailed
description
of
each
key's
function,
see
Chapter
3.
A
description
starting
with
(Shift)
is
the
secondary
function
of
the
key
,
which
is
available
by
pressing
the
BLUE
shift
key
(see
31).
1.
Display
displays
results
,
instrument
states
,
and
error
messages
.
2.
LINE
Switch
turns
the
4349B
ON
and
OFF
.
3.
Chassis
T
erminal
is
tied
to
the
instrument's
chassis
.
4.
INPUT
T
erminals
are
connection
ports
for
the
test
leads
.
(If
your
4349B
is
equipped
with
Option
001,
2
Channels
,
then
only
Ch
1
and
Ch
2
exist.)
INST
ALLA
TION
CA
TEGORY
I
5.
Channel
K
ey
selects
one
of
the
four
channels
to
display
.
6.
Measurement
P
arameter
K
ey
selects
the
measurement
parameter
to
be
displayed.
7.
Show
Setting
K
ey
changes
the
mode
of
the
Measurement
Settings
display
on
the
right
side
of
the
LCD
display
.
(Shift)
Display
Mode
key
selects
the
display
mode
.
8.
Range
A
uto/Hold
K
ey
toggles
the
measurement
range
mode
between
A
uto
and
Hold.
(Shift)
Range
Setup
K
ey
selects
the
measurement
range
.
9.
Left/Down
Arrow
K
ey
and
Right/Up
Arrow
K
ey
increases
or
decreases
the
setting
value
.
10.
V
oltage
Entry
K
ey
enters
the
test
voltage
value
,
which
is
used
with
the
measured
current
value
to
calculate
the
resistance
.
11.
Measurement
Time
K
ey
sets
the
measurement
time
to
10
ms
,
30
ms,
100
ms
or
400
ms.
12.
A
verage
K
ey
sets
the
averaging
rate
used
to
average
the
measurement
value
.
13.
Trigger
Mode
K
ey
selects
trigger
source
from
Internal,
Manual,
or
External.
(Shift)
Delay
K
ey
sets
the
trigger
delay
time
.
14.
Trigger
K
ey
triggers
a
measurement
when
in
the
manual
trigger
mode
.
1-4
Getting
Started
Содержание 4349B
Страница 1: ......
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 8: ......
Страница 20: ......
Страница 29: ...C Overload No Contact Operations Messages Instrument Errors Messages 2 GPIB Errors Messages 3 Index Contents 9 ...
Страница 42: ...4349B Figure 1 1 Power Cable Supplied 1 10 Getting Started ...
Страница 66: ......
Страница 88: ......
Страница 104: ......
Страница 146: ......
Страница 160: ......
Страница 173: ...4349B Figure 8 5 Current Measurement Additional Error Measurement Time 400 msec General Information 8 11 ...
Страница 176: ...4349B Figure 8 9 10 Additional Error Measurement Time 400 msec 8 14 General Information ...
Страница 210: ...4349B Figure B 1 Handler Interface Comparison Output Signals Diagram B 2 Handler Interface Installation ...
Страница 212: ...4349B Figure B 3 Handler Interface Input Signal Diagram B 4 Handler Interface Installation ...
Страница 216: ...4349B Figure B 4 A1 Main Board B 8 Handler Interface Installation ...
Страница 228: ......