You must be aware of the following safety
requirements and regulations.
Prior to installation, ensure that the local distribution
conditions (nature of gas and gas pressure) and the
adjustment of the appliance are compatible.
This appliance shall be installed in accordance with the
regulations in force and only in a well ventilated space.
Read the instructions before installing or using the
appliance.
In the UK
the regulations and standards are as
follows:-
In your own interests and that of safety, it is law that all
gas appliances be installed by competent persons.
CORGI registered installers undertake to work to safe
and satisfactory standards. Failure to install the
appliance correctly could invalidate any warranty or
liability claims and lead to prosecution. The cooker must
be installed in accordance with
z
All relevant British Standards/Codes of Practice,
in particular BS 5440 Part 2 2000,
z
or Natural Gas - BS 6172 : 1990 and BS 6891 : 1998
z
For LP Gas - BS 5482-1: 1994 (when the installation
is in a permanent dwelling), BS 5482-2: 1977 (when
the installation is in a caravan or other non-
permanent dwelling), or BS 5482-3: 1999, (when the
installation is in a boat).
z
The Gas Safety (Installation and Use) regulations
1998.
z
The relevant Building/IEE regulations.
In the Republic of Ireland
, the installation must be
carried out by a Competent Person and installed in
accordance with the current edition of I.S. 813 “Domestic
Gas Installations”, the current Building Regulations and
reference should be made to the current ETCI rules for
electrical installation.
Provision of Ventilation
This appliance is not connected to a combustion product
evacuation device. Particular attention shall be given to
the relevant requirements regarding ventilation.
In the UK
The room containing the cooker should have an air
supply in accordance with BS 5440 Part 2 : 2000. All
rooms require an openable window or equivalent, while
some rooms require a permanent vent in addition to the
openable window. The cooker should not be installed in
a bedsitting room with volume less than 20m
3
. If it is
installed in a room of volume less than 5m
3
an air vent of
effective area 100cm
2
is required; if it is installed in a
room of volume between 5m
3
and 10m
3
, an air vent of
effective area 50cm
2
is required; while if the volume
exceeds 11m
3
, no air vent is required.
If there are other fuel burning appliances in the same
room, BS 5440 Part 2 : 2000 should be consulted to
determine the requisite air vent requirements.
In the Republic of Ireland
Reference should be made to the current edition of IS
813 which makes clear the conditions that must be met
to demonstrate that sufficient ventilation is available.
Location of Cooker
The cooker may be installed in a kitchen/kitchen diner
but NOT in a room containing a bath or shower.
NOTE: An appliance for use in LPG shall not be
installed in a room or internal space below ground
level, e.g. in a basement.
28
Installation
All models are supplied set for use on either group H or for use on LP gas. THEY CANNOT BE CONVERTED
FROM ONE GAS TO THE OTHER.
This appliance is designed for domestic cooking only. Use for any other purpose could invalidate any warranty
or liability claim.