54
SE-Power FS STO-manual vers. 1.6 en.12.08.2015
9.1.3
Operating and environmental conditions
Transport
Temperature range
[°C]
–25 … +70
Air humidity
[%]
0 ... 95, at max. 40 °C ambient temperature
Maximum
transportation
duration
[Weeks]
Maximum 4 weeks over the entire product life cycle
Table 18:
Technical data: Transport
Storage
Storage temperature
[°C]
–25 … +55
Air humidity
[%]
5 ... 95, non-condensing or protected against
condensation
Permissible altitude
[m]
< 3000 (above sea level)
Table 19:
Technical data: Storage
Ambient conditions
Ambient temperature
[°C]
0 … +40 (outside the servo drive housing)
Cooling
By means of ambient atmosphere in the servo drive,
no forced ventilation
Permissible setup altitude [m]
< 2000 (above sea level)
Protection class
IP20 (mounted in the SE-Power FS).
Air humidity
[%]
Relative air humidity up to 90 %, non-condensing
Degree of contamination
in
accordance with
EN 61800-5-1
2
The integrated safety equipment requires compliance with
degree of contamination 2 and thus a protected fitting
space (IP54). This must always be ensured through
appropriate measures, e.g. through installation in a control
cabinet.
Table 20:
Technical data: Ambient conditions