Qualification of the specialist personnel (requirements for personnel)
The device may only be placed in operation by a qualified electrical engineer who is familiar
with:
installation and operation of electrical control systems,
the applicable regulations for operating safety-engineered systems,
the applicable regulations for accident protection and occupational safety, and
product documentation.
3.2.3
Diagnostic coverage (DC)
Diagnostic coverage depends on the connection between the servo drive with safety module
and the control loop system as well as the implemented diagnostic measures.
If a potentially hazardous disturbance is recognised during diagnosis, appropriate measures
for maintaining the safety level must be implemented.
Note
Check whether cross-circuit detection of the input circuit and the connection wiring
is required in your application.
If needed, use a safety switching device with horizontal cross-circuit detection to
activate the safety module.
3.2.4
Range of applications and certification
The servo drive with built-in safety module is a safety component in accordance with the
machinery directive; the servo drive bears the CE mark.
Standards and test values which the product must comply with and fulfils can be found in the
section
(
Appendix 9.1).
The product-relevant EU directives can be found