![Afag SE-Power FS Скачать руководство пользователя страница 26](http://html.mh-extra.com/html/afag/se-power-fs/se-power-fs_manual_2864007026.webp)
26
SE-Power FS STO-manual vers. 1.6 en.12.08.2015
4.4.2
Time behaviour for activating STO during operation with restart
displays the time behaviour starting from interruption of the control voltage to STO-
A/B, as well as the sequence required to allow the device to restart. The time specifications
can be found in
Notes:
The holding brake is activated via the servo drive, not a safety function.
The coasting of the motor, irrespective of brake activation/deactivation, is displayed.
The set point value is only activated when the holding brake delay T_BRAKE_V has
expired.
An error is triggered because the STO inputs are deactivated while the output stage is
active.
Figure 4:
Time behaviour when activating the safety function STO with restart
SE-Power FS Safety Module STO
STO-A / STO-B
Status LED
(~ C1/C2)
1
0
on
off
SE-Power FS
Holding brake
(optional)
1
0
T_STO-A/B_OFF
T_DIN5_LOW
STO – „Safe Torque Off” active
T_STO-A/B_ON
T_DRIVE_V
Speed
Servo drive enable
DIN5
24 V
0 V
1
0
„“Output stage enable”
(internal)
T_DIN5_SU
T_BRAKE_V_OFF
T_DRIVE_V
T_BRAKE_V_ON