45
SWP_5287500_00
8. INSTALLATION
8.1. PRELIMINARY
PROCEDURES
• Make sure the various unit
components are all intact.
• Make sure the various unit
components are all intact.
• Move the packaged section as near
as possible to the installation site.
• Do not stand equipment or weights on
top of the packaged unit.
8.2. CHOOSING
AN
INSTALLATION SITE
• On a fl at surface, the unit can
support the weight of the product
and its contents.
• Do not place the unit in areas
where fl ammable gases or acidic,
aggressive and corrosive substances
are present, as these could damage
the various components beyond
repair.
• If the unit is ducted, do not exceed
a total length of 10 metres.
8.3. HYDRAULIC
CONNECTIONS
Perform connection to the system
piping, so that the pipes:
•
Are not resting their entire weight on
the unit.
•
Allow maintenance procedures to
be carried out on the unit.
•
Allow access and removal of any
accessories installed.
Make sure the tank can be emptied
without being de-pressurised; use a
vacuum breaker valve if necessary. The
operating pressure of the boilers is 6 bar.
For correct commissioning, we
recommend:
• The installation of a safety valve and
a suitably-sized expansion tank.
• Connection of the sacrifi cial anode
(supplied) to the metal bulk.
• Testing the hardness of the mains
water (the warranty will not be valid
for hardness levels under 15°F and
over 40°F).
1 Rolling shutter
6
Membrane safety valve
2 Pressure reducer
7
Circulation pump
3 Control valve
8
Drain
4 Non-return valve
*
PWW and PEP models only
5 Drain valve
* * PEP models only
min. 0,5 m
min. 0,5 m
min. 0,3 m
min. 0,3 m
min. 1,2 m
hot water
heating delive
ry**
circulation (if necessary)
heating return
**
power
supply
alternative energy delivery
*
alternative energy
return
*
condensate
drain
cold water (connection
compliant with DIN 1988)
min. 0.5 m
min. 0.5 m
min. 0.3 m
min. 0.3 m
min. 1.2 m
Содержание SWP200
Страница 2: ......
Страница 31: ...DOMESTIC WATER HEAT PUMP installation maintenance SWP S W P _ 5 2 8 7 5 0 0 _ 0 0 GB ...
Страница 32: ......
Страница 61: ...POMPE À CHALEUR EAU SANITAIRE installation maintenance SWP SWP_5287500_00 FR ...
Страница 62: ......
Страница 91: ...BRAUCHWASSER WÄRMEPUMPE Installation Wartung SWP S W P _ 5 2 8 7 5 0 0 _ 0 0 DE ...
Страница 92: ......
Страница 121: ...BOMBA DE CALOR PARA AGUA SANITARIA instalación mantenimiento SWP S W P _ 5 2 8 7 5 0 0 _ 0 0 ES ...
Страница 122: ......
Страница 151: ......
Страница 152: ......
Страница 153: ......