AEQ
PHOENIX ALIO
68
•
It is mandatory that the called unit URI is specified in any of the following formats,
adequate for Direct SIP communications:
"<equipment’s_name>@<equipment’s_IP_address>" (for example:
[email protected]).
If the SIP port of the other end is not 5060 (standard SIP port), the identifier must
include the port in use:
For example: "[email protected]:5061".
VERY IMPORTANT: <equipment’s_name> must not be longer than 19 characters
•
Press the green "Call" button on the screen, to make the call.
•
Answer the call on the other unit, if "Autoanswer" option is not active.
•
You can observe the changes of status from OK to CONNECTED and synchronized
when calling from PROGRAM:
•
Verify that the "SYNC" LED beneath the "CALL" button is lighted in green to indicate
that the communication has been successfully established.
•
Send audio from one equipment to another verifying that the "Tx" and "Rx"
audio presence indicators change to green.
6.5.3.1. Ending an IP call in DIRECT SIP mode.
•
In order to hang call, just click on "CALL" button of the connected channel in one of
both codecs. A confirmation message will appear and the call will be disconnected after
acceptance.
6.5.3.2. Receiving and accepting an IP call in DIRECT SIP mode.
If the IP interface is correctly configured and automatic answer mode is OFF, when you receive
a call:
•
The unit and the application will provide acoustic warning. This can be disabled (for the
unit) at "Configuration"
"Miscellaneous"
"Buzzer and test".
•
The "CALL" button red LED of the called channel at the individual codec control window
in the remote control software corresponding to the unit that is receiving a call will blink
at the same time to warn the user.
•
In addition, if "Autoanswer" option is not active, an incoming call window will appear
showing the URI identifier of the caller unit: