Ground Resistance Tester Model 6471
33
To measure the resistances of auxiliary electrodes
H (Z)
and
S (Y)
, or if the resis
-
tance of the electrodes is too high
(see § 10.1), start the measurement with a long
press of the
START/STOP
button.
R
H
, R
S
will be displayed.
> 2s
EARTH
AUTO
H
S
E
Ω
k
Ω
k
Ω
NOTE:
Repeat the process at 52% and at 72% for the S electrode.
5.4.2 Full Method
A more thorough measurement can be obtained by taking measurement by mov
-
ing the
S (Y)
auxiliary electrode every 10% between
H (Z)
and
E (X)
and plotting
the results. A distinct plateau should result as shown below.
0
10
R10
R20
R30 R40
R50
% H - E
R60
R70
R80
R90
20
30
40
50
60
70
80
90
100
Take the average of the 3 or 4 readings on the
plateau to obtain the earth electrode resistance.
R =
R40 + R50 + R60 + R70
4