
Manipulator Manual of AIR20-A Industrial Robot
Project Maintenance Process
51
Table 13-2 grease changing attitude of operator13-2
Replace the
grease part
J1
J2
J3
J4
J5
J6
J1 axis reducer
170
°
0
°
90
°
any
any
any
J2 axis reducer
0
°
0
°
90
°
any
any
any
J3 axis reducer
0
°
45
°
-
45
°
any
any
any
Warning
Reducer oil temperature may be higher than 90
°
, to be replaced after
cooling.
Wear gloves to prevent allergic reactions.
Open the drain carefully and slowly to prevent oil spatter.
J1 axis reducer replacement grease process
Fig. 13-6 replace the lubricating grease of J1 axis reducer13-1
The replacement process is as follows:
1.
Run the manipulator as shown in Table 13-2.
2.
To prevent danger, turn off the power, hydraulic and pneumatic
sources connected to the robot.
3.
Place the waste oil collector near the grease outlet.
4.
Remove the grease outlet M10x1 plug, as shown in Fig. 13-6.
Grease Injection
Grease Outlet