ELECTRICAL SYSTEM
SERVICE MANUAL
ENGLISH
SC3000 26” Disc
9099052000
55
FUNCTION ELECTRONIC BOARD ERROR CODES
The function electronic board indicates a series of alarms in case of malfunction of one or more systems, and in case of abnormal
conditions detected in the input signals.
The alarms are shown on the display (71) (except “F6”) by 2 signs following each other: “AL” and “XX”, where XX is the alarm code
(see the descriptions in the following tables).
Also, the alarms are repeated (in case of display malfunction) by the diagnostic LEDs (yellow and red) on the electronic board, as
described in the following tables.
General Alarms (YELLOW LED + RED LED FLASHING)
Alarm Code
= No. of
flashes
Meaning
Condition
Effect
G2
EEPROM error
EEPROM error
Function block + Default setting
reset
G3
General thermal protection
Heatsink temperature > 90 °C
Function block
G4
Blown F2 fuse
V > 1V on F2
Function block
G5
Wrong KEY sequence
Wrong key sequence
Function block
G6
No signal from BATTERY CHARGER
No signal from battery charger
The charging battery phase is not
shown
G7
Undervoltage
B+ - B- < THRESHOLD2 for t >10”
Function block
G8
Serial communication error with dashboard
electronic board
No signal or decoding error
No block
G9
Battery voltage drop
DeltaV (neg.)> 3V on battery voltage
Drive electromagnetic
brake block
Function Alarms (RED LED FLASHING)
Alarm Code
= No. of
flashes
Meaning
Condition
Effect
F2
BRUSH motor amperometric protection
Voltage higher than the safety threshold
Brush electromagnetic switch
output block
F3
VACUUM SYSTEM amperometric protection
Vacuum system abnormal electrical input >
30A for T>10s
Vacuum system block
F4
DECK ACTUATOR position irregularity
End-of-stroke microswitch configuration not
plausible or end-of-stroke not reached within
10”
Deck actuator block
F5
VACUUM SYSTEM power section damage
CC MOSFET
Vacuum system block
F6
PRESSURE SWITCH signal fault
Pressure switch Vout > 4.0V
Water level visualisation missing
+ water flow and % detergent
management fault
F7
VACUUM SYSTEM output short circuit
I > 2 * 50A
Vacuum system block
F8
Function general relay fault
Always closed / opened
Function block
All “general” and “function” alarms, and their relevant effects remain until reset from KEY input. In case of simultaneous errors, the
one with greater priority is shown first (priority order is opposite to the number of flashes).
A2 ENGLISH(2).indd 55
29/07/2011 17.03.09
Содержание SC3000 26" Disc
Страница 2: ......
Страница 28: ...BRUSHING SYSTEM ENGLISH SERVICE MANUAL 26 9099052000 SC3000 26 Disc WIRING DIAGRAM P100384A ...
Страница 35: ...RECOVERY WATER SYSTEM SERVICE MANUAL ENGLISH SC3000 26 Disc 9099052000 33 WIRING DIAGRAM P100387A ...
Страница 36: ...RECOVERY WATER SYSTEM ENGLISH SERVICE MANUAL 34 9099052000 SC3000 26 Disc ...
Страница 39: ...PARKING BRAKE SYSTEM SERVICE MANUAL ENGLISH SC3000 26 Disc 9099052000 37 WIRING DIAGRAM P100389A ...