![ADB Safegate IDM 8000 Скачать руководство пользователя страница 87](http://html1.mh-extra.com/html/adb-safegate/idm-8000/idm-8000_user-manual_2847402087.webp)
U2 output voltage / Byte 8
The value is always 0-125 in which 125 is the maximum output voltage of the CCR which again depends on the CCR size. This means that
the PLC (or the PC) must have the CCR size as a parameter in order to display the actual U2. One digit is CCR size (VA) / 6.6A / 125.
P2 output actual power / Byte 9
The value is always 0-125 in which 125 is the maximum power of the CCR which again depends on the CCR size. This means that the PLC (or
the PC) must use the CCR size parameter when displaying the actual P2- reading. One digit means CCR size (W) / 125
CCR type and size parameters / Byte 11
This byte indicates the CCRs type and size to control system and can be used to automatically update these parameters in the control
system.
Three first bits (80-82, Lsb=80) define the CCR type in binary coded format: 0=normal CCR, 1=direction changer, 2-6= 2-6 circuit selectors
(Dec values)
Four last bits (84-87, Lsb=84) define the CCR size in binary coded format: 1=2,5kVA, 2=3kVA, 3=4kVA, 4=5kVA, 5=7,5kVA, 6=10kVA,
7=12,5kVA, 8=15kVA, 9=17,5kVA, 10=20kVA, 11=25kVA and 12=30kVA (Dec values).
Redundant duplicated interface / other interface control bit status / Byte 12
This information is provided for the control system to facilitate control channel / interface monitoring.
Displays which can be calculated from the above values in the control system
- S2 = I2 * U2 = Apparent power taken by the load
-Pf2 = P2 / S2 = load power factor, how inductive the load is ( lamp faults etc)
UM_IDM-8000, Rev. 1.7, 2021/05/06
75
Copyright
©
ADB Safegate, All Rights Reserved
Содержание IDM 8000
Страница 1: ...IDM 8000 CCR User Manual UM_IDM 8000 Rev 1 7 2021 05 06 ...
Страница 2: ......
Страница 8: ...IDM 8000 TABLE OF CONTENTS viii Copyright ADB Safegate All Rights Reserved ...
Страница 10: ...IDM 8000 List of Figures x Copyright ADB Safegate All Rights Reserved ...
Страница 12: ...IDM 8000 List of Tables xii Copyright ADB Safegate All Rights Reserved ...
Страница 18: ...IDM 8000 Safety 6 Copyright ADB Safegate All Rights Reserved ...
Страница 20: ...IDM 8000 About this Manual 8 Copyright ADB Safegate All Rights Reserved ...
Страница 76: ...IDM 8000 Troubleshooting 64 Copyright ADB Safegate All Rights Reserved ...
Страница 92: ...IDM 8000 Appendix F Parallel remote control example 80 Copyright ADB Safegate All Rights Reserved ...
Страница 100: ...IDM 8000 Appendix I Commissioning test report form 88 Copyright ADB Safegate All Rights Reserved ...
Страница 104: ...IDM 8000 Appendix J Spare part list 92 Copyright ADB Safegate All Rights Reserved ...
Страница 106: ...IDM 8000 Appendix K Components of electronics 94 Copyright ADB Safegate All Rights Reserved ...
Страница 107: ...Appendix L Appendix L CCR components UM_IDM 8000 Rev 1 7 2021 05 06 95 Copyright ADB Safegate All Rights Reserved ...
Страница 113: ...UM_IDM 8000 Rev 1 7 2021 05 06 101 Copyright ADB Safegate All Rights Reserved ...
Страница 114: ...IDM 8000 Appendix M Output Terminals 102 Copyright ADB Safegate All Rights Reserved ...
Страница 118: ......