5.3.1 Mains Connection
•
Connect the mains supply cable into the CCRs main switch terminals L, N (or L2), PE.
•
Make sure that the cable size is sufficient for the CCR rating
•
Make sure that a proper earth for the CCR is provided. Although the earth copper wire is provided with the supply,
additional safety grounding of the CCR is recommended.
•
Make sure that the fuse bank in the supplying low voltage switchboard is correct for the supply cable and the CCR rating.
See table below
•
Equipment according to IEC 61000-3-4, provided Rsce min = 175 as verified by the supply authority.
•
It is recommended that the CCRs should be balanced evenly on the supply phases in order to provide as equal load for
the 3 phases as possible, in all operational situations.
NOTE! The recommendations below should be considered as guidelines. Always follow national requirements for LV-boards and
supply cables, which deviate from the values below.
CCR size Supply
Main fuse in CCR
Recommended size of fuse or circuit
breaker for supply power in LV-
board
Recommended minimum
cross section of supply
copper wire from LV-board
to CCR
Recommended minimum
cross section of earth
copper wire from LV-board
to CCR
3 kVA
230 VAC 2 pole 20 A, c-curve
2 pole 25 A, c-curve
6 mm
2
4 mm
2
4 kVA
230 VAC 2 pole 25 A, c-curve
2 pole 35 A, c-curve
10 mm
2
6 mm
2
5 kVA
230 VAC 2 pole 40 A, c-curve
2 pole 50 A, c-curve
10 mm
2
6 mm
2
400 VAC 2 pole 20 A, c-curve
2 pole 25 A, c-curve
6mm
2
4 mm
2
7.5 kVA 400 VAC 2 pole 25 A, c-curve
2 pole 35 A, c-curve
10 mm
2
6 mm
2
10 kVA
230 VAC 2 pole 63 A, c-curve
2 pole 50 A, c-curve
25 mm
2
16 mm
2
400 VAC 2 pole 40 A, c-curve
2 pole 50 A, c-curve
10 mm
2
10 mm
2
12.5 kVA 400 VAC 2 pole 50 A, c-curve
2 pole 63 A, c-curve
16 mm
2
10 mm
2
15 kVA
230 VAC 2 pole 80 A, c-curve 2
pole
2 pole 100 A, c-curve
35 mm
2
25 mm
2
400 VAC 50 A, c-curve
2 pole 63 A, c-curve
16 mm
2
10 mm
2
17.5 kVA 400 VAC 2 pole 63 A, c-curve
2 pole 80 A, c-curve
25 mm
2
16 mm
2
20 kVA
230 VAC 2 pole 100 A, c-curve
2 pole 125 A, c-curve
50 mm
2
35 mm
2
400 VAC 2 pole 80 A, c-curve
2 pole 100 A, c-curve
35 mm
2
25 mm
2
25 kVA
400 VAC 2 pole 80 A, c-curve
2 pole 100 A, c-curve
35 mm
2
25 mm
2
30 kVA
400 VAC 2 pole 100 A, c-curve
2 pole 125 A, c-curve
50 mm
2
35 mm
2
IDM 8000
Installation
52
Copyright
©
ADB Safegate, All Rights Reserved
Содержание IDM 8000
Страница 1: ...IDM 8000 CCR User Manual UM_IDM 8000 Rev 1 7 2021 05 06 ...
Страница 2: ......
Страница 8: ...IDM 8000 TABLE OF CONTENTS viii Copyright ADB Safegate All Rights Reserved ...
Страница 10: ...IDM 8000 List of Figures x Copyright ADB Safegate All Rights Reserved ...
Страница 12: ...IDM 8000 List of Tables xii Copyright ADB Safegate All Rights Reserved ...
Страница 18: ...IDM 8000 Safety 6 Copyright ADB Safegate All Rights Reserved ...
Страница 20: ...IDM 8000 About this Manual 8 Copyright ADB Safegate All Rights Reserved ...
Страница 76: ...IDM 8000 Troubleshooting 64 Copyright ADB Safegate All Rights Reserved ...
Страница 92: ...IDM 8000 Appendix F Parallel remote control example 80 Copyright ADB Safegate All Rights Reserved ...
Страница 100: ...IDM 8000 Appendix I Commissioning test report form 88 Copyright ADB Safegate All Rights Reserved ...
Страница 104: ...IDM 8000 Appendix J Spare part list 92 Copyright ADB Safegate All Rights Reserved ...
Страница 106: ...IDM 8000 Appendix K Components of electronics 94 Copyright ADB Safegate All Rights Reserved ...
Страница 107: ...Appendix L Appendix L CCR components UM_IDM 8000 Rev 1 7 2021 05 06 95 Copyright ADB Safegate All Rights Reserved ...
Страница 113: ...UM_IDM 8000 Rev 1 7 2021 05 06 101 Copyright ADB Safegate All Rights Reserved ...
Страница 114: ...IDM 8000 Appendix M Output Terminals 102 Copyright ADB Safegate All Rights Reserved ...
Страница 118: ......