Note
Exception: the optical cover of the ICAO threshold is transparent and does not show the color of the LEDs.
2.6 Frangible coupling
A: Frangible coupling
B: Weakening groove
C: Mounting flange A
The fixture includes a frangible coupling with a weakening groove.
2.7 Runway Threshold combined with Runway End fixtures
If required the ICAO Runway Threshold/End position can be supplied either with two rows of unidirectional fixtures for each
of the applications separately. Alternatively, it can be supplied with a bidirectional fixtures with both applications.
In the former case, the Threshold Green fixtures are not equipped with toe-in and shall be installed upon appropriate rotation
of the fixture on the stem with respect to the mounting plate. In the latter case, only the centerline fixture has no toe-in on
the green side. Positions displaced from the runway centerline shall be installed according to the scheme below.