Note
The steps for the Earthing cable only apply if one is installed.
Remove - step 1
1. Remove the complete optical head. See §
Part replacement - complete optical head
2. Compress the cable strain relief bushing (A) and pull it out of the body support (B). Use the pliers.
3. Remove the screw (C) for the Earthing cable.
Remove - step 2
1. Open the cable strain relief bushing (A).
2. Pull the cable lead (C) and the Earthing wire (B) out of the fixture.
3. Dispose of the damaged parts.
Install
1. Pull the cable lead (A) and the Earthing cable (B) through the hole (C) of the body support.
2. Put the cable lead and the Earthing cable in the cable strain relief bushing (D): I.
3. Install the Earthing cable on the screw for the Earthing cable (E).
4. Install the screw for the Earthing cable. See §
(torque).
AM.03.120e, Rev. 3.4, 2019/03/29
31
Copyright
©
ADB Safegate, All Rights Reserved
Содержание EREL
Страница 1: ...EREL ERES User Manual AM 03 120e Rev 3 4 2019 03 29 ...
Страница 2: ......
Страница 10: ...EREL ERES Safety 4 Copyright ADB Safegate All Rights Reserved ...
Страница 42: ...EREL ERES Maintenance 36 Copyright ADB Safegate All Rights Reserved ...
Страница 49: ...AM 03 120e Rev 3 4 2019 03 29 43 Copyright ADB Safegate All Rights Reserved ...
Страница 50: ......