2.8 Monitoring (option)
The monitoring option is available. You can use the monitoring option with the Lamp Fault Detection of Constant Current
Regulators or with Individual Light Control and Monitoring Systems (ILCMS) that check the status of the light by performing a
continuity test on the secondary of the ILCMS remote module. The monitoring option does a check on the light. In case of a
failure of the light, the failure is detected by the electronics embedded in the light.
Warning
Ask your local representative for the compatibility of the ILCMS system and the light.
2.9 Arctic kit (option)
The arctic kit option is available, in compliance with FAA Engineering Brief EB67.
If the fixture has the arctic kit option, a thermostatically controlled heater prevents ice and snow buildup. This prevents a
decrease of light output. This heater melts ice similar to traditional incandescent fixtures. The heater goes on only when the
temperature drops below 0 degrees Celcius, to reduce the energy consumption.
The arctic kit is available on both glass and polycarbonate options.