Connect
1. Perform a fixture operation test. See §
.
2. If the fixture does not come on:
a. Replace the complete optical head. See §
Part replacement - complete optical head
b. Perform an operation test. See §
c. If the fixture does not come on, contact ADB SAFEGATE
Assemble
1. Reinstall the complete optical head. See §
Part replacement - complete optical head
4.3.12 Part replacement - fuse resistor (monitoring option)
Parts: See §
.
•
Fuse resistor kit
Tools:
•
Pliers
Disassemble
1. Remove the complete optical head. See §
Part replacement - complete optical head
.
2. Pull the legs of the fuse resistor (A) and remove it from the sockets.
3. Dispose of the old fuse resistor.
Assemble
1. Insert the legs of the new fuse resistor in the sockets.
2. Reinstall the complete optical head. See §
Part replacement - complete optical head
4.3.13 Assemble the complete optical head
Parts: See §
.
•
Body
•
Optical kit
•
LED MCPCB screws
•
Optical cover
•
Optical cover gasket
•
Cooling block
•
Cooling block washers
•
Cooling block gasket
•
Cooling block screws
EREL / ERES