Installation
59/ 80
LipuJet-P-OB / -OD, LipuJet-P-OA / -OAP
EN
4 Installation
4.1 Installation area and preconditions
The following preconditions have to be
considered:
■
The installation room must be separate,
dry and equipped with a properly
working ventilation and aeration system.
■
Grease separators must be installed on
level surfaces.
■
Appropriate illumination has to be
available
■
Appropriate power and drinking water
supply must be available
■
The open space above the separator
covers must be at least 50 cm for
inspection and maintenance works.
■
The open space surrounding the
separator must be at least 50 cm.
ACO Haustechnik
Installation area
Minimum
50 centimetres!
ACO Haustechnik
Installation area
Minimum
50 centimetres!
Minimum
50 centimetres!
4.2 Inflow piping arrangement
The inlet connection is designated for waste water pipes with corresponding outside
diameters. The connection between pipe system and separator inflow connection can
be carried out with appropriate sockets (pipes of PE/PP/PVC), welding sockets (PE) or
clamping rings (pipes of plastic, cast iron).