User’s Guide
26
SAF-TE Enclosure Management
What is SAF-TE?
SAF-TE stands for SCSI Accessed Fault-Tolerant Enclosures. It is an
enclosure management technology. A SAF-TE-compliant enclosure
monitors the fan temperature, power supply, UPS and also provides
drive status LED’s. The SAF-TE enclosure connects to the RAID
Controller via a SCSI connector. The RAID controller communicates
with the SAF-TE enclosure with standard SCSI commands.
SAF-TE Support
Drive Status
Indicators
UPS Failure
Signal Input
Power Supply
Failure
Signal Input
Cooling Fan
Failure
Signal Input
Temperature Alert
Signal Input
SAF-TE
Chipset
SCSI
RAID
Controller
Front Panel
error alert
GUI RAID Manager
error alert
•
SAF-TE chipset connects to the drive channel of the
controller together with the other SCSI drives.
How Does SAF-TE work?
The SAF-TE device (often a back plane within a drive-bay enclosure)
must occupy a connector on one of the drive channels’ SCSI cables.
The presence of a SAF-TE device will be detected and its presence
will be displayed in both the RS-232 terminal emulation and the Acer
RAID Manager programs.
Acer RAID Manager
error alert
Содержание AcerAltos 3102RS
Страница 1: ...AcerAltos 3102RS AcerAltos 3102RS Ultra SCSI to Ultra SCSI RAID Controller User s Guide ...
Страница 18: ......
Страница 20: ......
Страница 24: ......
Страница 55: ...Chapter 3 Functional Descriptions 37 Drive E now has a capacity just under 1800MB ...
Страница 56: ......
Страница 64: ...User s Guide 46 Insert RAID Controller Main Board Daughter Board Insert ...
Страница 202: ......
Страница 218: ......
Страница 276: ......
Страница 290: ......
Страница 296: ...User s Guide G 2 ...