Chapter 9 Redundant Controller
197
The message "Redud Ctlr LG Assign Sec
Ctlr?" will appear. Press
ENT
for two
seconds to confirm. The logical drive has
now been assigned to the Secondary
controller.
Map the LUN to the Secondary controller. The Secondary controller
must have a host SCSI ID created. (Create the Secondary controller’s
SCSI ID or add a SCSI ID channel in "View and Edit SCSI Channels"
of the Main Menu.)
Reset the two controllers and host computers for the settings to take
effect.
Only firmware versions 2.11 and above can assign
logical drives to the primary or secondary
controllers. Firmware versions earlier than 2.11 will
automatically assign a logical drive to the primary
controller and are unable to assign a logical drive to
the secondary controller.