User’s Guide
18
Automatic Rebuild and Manual Rebuild
Automatic Rebuild
One member drive
fails in logical drive
Any
Local Spare Drive
assigned to this
logical drive?
Yes
Yes
Rebuild using the
Local Spare Drive
Any
Global Spare Drive
assigned to this
logical drive?
Rebuild using the
Global Spare Drive
No
No
Wait for
manual rebuild
When a member drive in the logical drive failed, the controller will first
check whether there is a Local Spare Drive assigned to this logical
drive. If yes, it will automatically start to rebuild.
If there is no Local Spare Drive available, the controller will search for
a Global Spare Drive. If there is a Global Spare Drive, it will
automatically rebuild the logical drive.
If neither Local Spare Drive nor Global Spare Drive is available, the
controller will not try to rebuild unless the user applies a forced-manual
rebuild.