User’s Guide
218
Baud rate, Data Routing and Enable Terminal Emulation
In the Communication Parameter menu, select “RS-232 Port
Configuration”. Choose “COM 2 Configuration” to configure the COM 2
port of the AA-3102RS RAID Controller.
Set the baud rate of the modem and the client terminal emulation
program. In this example, COM 1 and COM 2 are used for terminal
emulation at the same time. The baud rate for both COM 1 and COM
2 must be the same.
Set the “Data Routing....” to “Data Routing Direct to Port”, and enable
the Terminal Emulation. The Modem is now ready to answer the dial-
in connections.
•
If COM 1 and COM 2 are both used as terminal
emulation, the baud rate must be the same.
•
The baud rate setting in the client (remote site)
terminal emulation program must be the same
as the baud rate setting of the controller’s COM
port.