Appendix E Troubleshooting Guide
E-3
PROBLEM
CHECK
The logical drive states “INVALID”.
1. “Optimization for .... I/O”, when
creating the logical drive in Cache
Parameter, is different from the
current setting.
2. Change “Optimization for ...I/O” to
the opposite setting and reset the
controller.
In “View and Edit SCSI Drives” or
“View and Edit SCSI Channels”,
the speed is only “20.8Mhz”, not
“40Mhz”
1. “20.8Mhz” is SCSI sync
frequency, not transfer rate.
2. Refer to Appendix B, SCSI cable
Specification, for details.
All settings are too complex to
remember.
1. After the system installation
completes, write down all the
settings and related information in
“Appendix H Take Record of the
Settings” for future reference.
Upon replacing the failed controller
with a new one during Redundant
controller connection, nothing
appears on the LCD of the new
controller.
1. Set the new controller as
“redundant controller enabled”
before connecting to the active
controller.
2. Connect the new controller to the
active controller and choose
“Deassert failed controller” on the
active controller.
3. Refer to Chapter 9, Redundant
Controller, for more details.
Содержание AcerAltos 3102RS
Страница 1: ...AcerAltos 3102RS AcerAltos 3102RS Ultra SCSI to Ultra SCSI RAID Controller User s Guide ...
Страница 18: ......
Страница 20: ......
Страница 24: ......
Страница 55: ...Chapter 3 Functional Descriptions 37 Drive E now has a capacity just under 1800MB ...
Страница 56: ......
Страница 64: ...User s Guide 46 Insert RAID Controller Main Board Daughter Board Insert ...
Страница 202: ......
Страница 218: ......
Страница 276: ......
Страница 290: ......
Страница 296: ...User s Guide G 2 ...