User’s Guide
E-2
PROBLEM
CHECK
Cannot detect SCSI drive
1. Check drive power connections.
2. Check drive SCSI cable
connections.
3. Check ID numbers (must be
unique for each device on the
same SCSI channel).
Host cannot detect AA-3102RS
1. Check host SCSI cable
connections.
2. Check SCSI port to LUN assign-
ment.
3. Check logical drive mapping to
LUN.
Parity error detected
1. DRAM SIMM should be replaced.
Logical drive failure detected
during boot-up
1. Check proper installation or
connection of the drives (use the
"View SCSI drives" function to help
locate the problem).
System is not stable after running
for a period of time.
1. SCSI cable must be shorter than 3
meters.
2. Make sure terminators are proper
installed.
3. Power supply voltage must be
within specification.
4. Check the enclosure’s inner
temperature.
When using “Scan New SCSI
Drive” and the desired ID is empty,
an empty drive entry appears.
1. Refer to Chapter 7 or Chapter 8
section “Scanning New SCSI
Drive” on how to remove the
empty drive entry.
The RS-232C Terminal Interface is
not working.
1. Check RS-232C cable connections.
2. Check Baud Rate.
3. Enable Terminal Emulation.
4. Data Routing Direct to Port.
When choosing “Configure Modem
Port”, the screen is full of “ Comm
Buffer Overflow”.
1. “Terminal Emulation” should be
enabled after all modem
configuration are completed.
Содержание AcerAltos 3102RS
Страница 1: ...AcerAltos 3102RS AcerAltos 3102RS Ultra SCSI to Ultra SCSI RAID Controller User s Guide ...
Страница 18: ......
Страница 20: ......
Страница 24: ......
Страница 55: ...Chapter 3 Functional Descriptions 37 Drive E now has a capacity just under 1800MB ...
Страница 56: ......
Страница 64: ...User s Guide 46 Insert RAID Controller Main Board Daughter Board Insert ...
Страница 202: ......
Страница 218: ......
Страница 276: ......
Страница 290: ......
Страница 296: ...User s Guide G 2 ...