Chapter 12 Fault-Bus
235
How Does the Fault-Bus Work?
Fault-Bus
Drive Failure LEDs
Signal Output
Fan
Power
Supply
Temp.
Sensor
UPS
Power
Supply
User designed / 3rd party circuit
Rise or sink output signals
according to the information detected/received
Cooling
Fan
Failure
UPS
Failure
Power
Supply
Failure Signal
Elevated
Temperature
Alert
Front Panel
error alert
GUI RAID Manager
error alert
RS-232C
Terminal Interface
error alert
ATTEN
BUSY
POWER
ENT
ESC
RAID
Controller
Error Signals Input
Fault-bus only collects the signals, it does not detect the temperature,
fan rotation, power supply failure or the UPS power failure. A user
designed or a 3rd party circuit is necessary for Fault bus.
The user designed / 3rd party circuit must do the following:
•
Detect the fan rotation, and rise up or sink down the “fan” signal
of the Fault-bus (pin 34 in the left Fault-bus connector) according
to the detected infomation. When the fan fails to rotate, activate
the signal. When the fan rotates properly, keep the signal
inactive. If more than one fan is supported in this enclosure,
detect the fan rotation of each fan and simply combine them into
one signal.
Acer RAID Manager
Содержание AcerAltos 3102RS
Страница 1: ...AcerAltos 3102RS AcerAltos 3102RS Ultra SCSI to Ultra SCSI RAID Controller User s Guide ...
Страница 18: ......
Страница 20: ......
Страница 24: ......
Страница 55: ...Chapter 3 Functional Descriptions 37 Drive E now has a capacity just under 1800MB ...
Страница 56: ......
Страница 64: ...User s Guide 46 Insert RAID Controller Main Board Daughter Board Insert ...
Страница 202: ......
Страница 218: ......
Страница 276: ......
Страница 290: ......
Страница 296: ...User s Guide G 2 ...